MAURY USCG vessel records
← All vessels

CS JINAN

CS JINAN is a 2019 freight ship. The Coast Guard has recorded 7 inspections since 2019, most recently in March 2026, along with 6 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2019 to 2026. Most recent: inspection, 4 March 2026.

Built
2019
Last inspected
4 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9830082
1554073
Flag
HONG KONG
Maury page id
psix-1554073

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 4 calendar years (2019–2026)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it44153 - Convention (Subpart B), Gross Ton
27609 - Convention (Subpart B), Net Ton
81579 - Dead Weight, Metric Ton
95298 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 7

4 March 2026 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314282
31 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924405
30 May 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7915874
20 May 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7915932
19 January 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118846
3 January 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118845
15 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6709659

Deficiency record · 6

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 March 2026 No resolution recorded
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted within 90 days. 74 SOLAS IX/3 ISM Code 10.1 ac
Action required: 705 - Other - as specified
Due 2 June 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 March 2026 Resolved
The training manual which may comprise several volumes shall contain the instructions and information required in paragraph 2.3.4 in easily understood terms and illustrated wherever possible. PSCO observed that vessel's training manual is missing multiple required items for fire-fighting. 74 SOLAS (cons) II-2/ 15.2.3.3 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Received class report attesting to missing training manual items
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2026 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: .1 fire protection systems and appliances shall be maintained and ready for use. PSCO found six dry chemical fire extinguishers were overcharged with no manufacture's instructions showing overcharge allowance. 74 SOLAS (cons) II/2 15.2.3.3 10c
Action required: 10 - Deficiency Rectified
Due 4 March 2026
Resolved 4 March 2026
Resolution: Verified vessel had spares and all were properly replaced IAW fire control plan.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 March 2026 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed low pressure from the emergency fire pump. Adequate pressure was unavailable for the first hour after the test was requested. Crew rectified issue and Coast Guard verified. 74 SOLAS (cons) II-2/14.2.1.2 10c
Action required: 10 - Deficiency Rectified
Due 4 March 2026
Resolved 4 March 2026
Resolution: Crew was able to gain adequate pressure after closing isolation valve.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2026 Resolved
In addition to the requirements contained elsewhere in the present regulations ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO identified leaking cargo hatch cover hydraulic jacks in six locations throughout ships upper deck. 74 SOLAS (cons) II/1 3-1 10c
Action required: 10 - Deficiency Rectified
Due 4 March 2026
Resolved 4 March 2026
Resolution: Crew replaced all zirc fittings that were leaking
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2026 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed 8 electrical bonding wires deteriorated or missing around junction boxes on deck 74 SOLAS (cons) II-I/45.1.3 10c
Action required: 10 - Deficiency Rectified
Due 4 March 2026
Resolved 4 March 2026
Resolution: Crew replaced all broken bindings on deck.

Ownership record