MAURY USCG vessel records
← All vessels

NORWEGIAN ENCORE

NORWEGIAN ENCORE is a 2019 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 2019, most recently in June 2026, along with 16 deficiencies and 2 operational controls.

Records from 2019 to 2026. Most recent: inspection, 14 June 2026.

Built
2019
Last inspected
14 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9751511
1554608
Flag
BAHAMAS, THE
Maury page id
psix-1554608

Documentation record

Tonnage as PSIX records it169116 - Convention (Subpart B), Gross Ton
11700 - Dead Weight, Ton
76889 - Displacement, Ton
153398 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 51

14 June 2026 COC-CVE Annual · PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8404520
5 May 2026 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8367599
29 November 2025 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8274975
22 June 2025 PSC A · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8164264
7 April 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8106802
26 January 2025 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8072108
22 December 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8049531
23 June 2024 PSC A · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7937751
5 June 2024 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7932080
8 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7930122
30 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7921811
3 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7879802
10 December 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7836993
3 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842562
19 October 2023 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7811330
27 June 2023 PSC A · Deficiency Check · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7724410
21 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7796139
6 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7762592
23 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7749452
16 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7739704
28 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643529
25 January 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7671033
12 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7639600
3 January 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7615510
30 December 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7614644
28 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7600899
17 November 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7595945
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576834
24 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542652
9 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529246
1 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7522583
29 July 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519784
5 July 2022 Ballast Water Examination · COC-CVE Annual
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7497712
16 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479725
6 June 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7476401
21 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7415901
28 February 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7403381
30 January 2022 PSC B · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7386237
16 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7381050
7 October 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7328633
1 October 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7324981
1 October 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7324985
18 August 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7290411
18 August 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7290437
26 July 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7268957
26 July 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7268961
19 July 2021 COC-CVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7235178
19 July 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7261186
6 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6936065
11 November 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Initial · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6852141
20 May 2019 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6688400

Deficiency record · 16

10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 14 June 2026 Resolved
Nautical charts and nautical publications, such as sailing directions, lists of lights, notice to mariners, tide tables and all other nautical publications necessary for the intended voyage, shall be adequate and up to date. PSCO observed ECDIS that did not properly receive week 24 chart update.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 16 June 2026
Resolved 16 June 2026
Resolution: ECDIS properly received week 24 update.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 June 2026 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photolumiescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed 20 feet of low-location lighting blocked by electric wheelchairs in category 3 Deck 5 corridor forward of lecture room and 5 feet of photoluminscent tape blocked by an ATM outside of the financial room on Deck 4.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2026
Resolved 16 June 2026
Resolution: Crew moved wheelchairs and added photoluminescent tape to ATM.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. The escape route from the gym was blocked by bikes. 74SOLAS(24)II-2/13.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 November 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 June 2025 Resolved
Safe escape routes shall be provided. Consultation Room A in Passenger Gym (Deck 16) is equipped with an equivalent level of safety for immediate notification for escape of the crew normally employed in the space. PSCO observed the notification alarm inoperable. 74 SOLAS 20 II-2/13.1.1, 10c 74 SOLAS 20 II-2/13.1.1 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 June 2025
Resolved 22 June 2025
Resolution: Crew fixed fire alarm to sound in Consultation Room A.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 June 2025 Resolved
Portable radio devices used to comply with paragraph (a) of this section during the transfer fo flammable or combustible liquids must be intrinsically safe. PSCO observed non-intrinsically safe radios being using during active bunker operation. 33 CFR 155.785 (d), 10c 33 CFR 155.785(d) 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 June 2025
Resolved 22 June 2025
Resolution: Crew obtained intrinsically safe radios to be used during bunkering operations.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 June 2025 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Aft Mooring Deck, deck 5, MVZ 6 is a dual category (10)(5) space where storage of combustibles is prohibited. PSCO observed storage of compressed gas O2 cylinders. 74 SOLAS 20 II-2/9.2.2.3.2.2, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 June 2025
Resolved 22 June 2025
Resolution: Crew removed compressed gas O2 cylinders.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 December 2024 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. PSCO's observed thumb latch on secondary escape door on Deck 8 in Cavern Club. 74 SOLAS 20 II-2/13 3 2 6.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 December 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 December 2024 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO's observed section of low location lighting on Deck 7/Fire zone 6 near Manhattan restaurant inoperable. 74 SOLAS 20 II-2/13 3.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 December 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 June 2024 Resolved
07120 - The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the escape exits. Additionall, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Stretcher outside of hospital space is errantly stored blocking low-location escape lighting. 74 SOLAS 20 II-2/13.3.2.5.1, 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 June 2024
Resolved 23 June 2024
Resolution: Deficiency rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 June 2024 Resolved
07123 - Fire Protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed 01 fire hoses on deck 06 fire zone 01 leaking near the nozzle. 74 SOLAS 20 II-2/14.1.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 June 2024
Resolved 23 June 2024
Resolution: Deficiency rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2023 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Non-combustible waste receptacles were being used in the main galley, and backstage theater area amongst various other locations throughout the ship for garbage collection. 74SOLAS 20 II-2/4.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 30 June 2023
Resolution: All crew working in the areas received documented training in regards to segregation of garbage and garbage management to ensure combustible waste receptacles were appropriately used.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 27 June 2023 Resolved
Prior to being assigned shipboard duties on board passenger ships, seafarers shall have completed the training required by paragraphs 4 to 7 below IAW their capacity, duties and responsibilities. During abandon ship drill, PSCOs observed several stairway guides in the forward and aft passenger stairtowers who were unfamiliar with their duties and basic shipboard safety. STCW V/2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2023
Resolution: The 4 individuals identified were provided additional safety training and completed a safety exam to confirm/document sufficient safety knowledge.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 June 2023 Resolved
Doors and door frames in "B" class divisions...shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. Door B-06-1-001 IVO carpenters storeroom was misaligned allowing for a gap on the top, between the door and door frame. 74 SOLAS 20 II-2/9.4.1.2.1
Action required: 10 - Deficiency Rectified
Resolved 27 June 2023
Resolution: Door re-aligned.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 July 2021 Resolved
PSCO Discovered multiple aft stairwell guides were unfamiliar with assembly station chart and were unable to guide passengers to assigned assembly stations. SOLAS 20 II-2/15.3.1 10.C
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
Resolution: Assembly station cards were updated and distributed to assigned personnel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 July 2021 Resolved
Fire doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees. PSCO discovered FSC 3-5-014 did not fully latch during closure. SOLAS 20 II-2/9.4.1.1.5, 10c
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
Resolution: Maintenance personnel adjusted door and performed a satisfactory closure test.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 July 2021 Resolved
Launching appliances and area of water shall be adequately illuminated by lighting. PSCO discovered two embarkation lights on embarkation deck port side inoperable. SOLAS 20 III/16.7
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
Resolution: Maintenance team replaced lighting and conducted a satisfactory functional test.

Ownership record