MAURY USCG vessel records
← All vessels

DIAMOND GAS ROSE

DIAMOND GAS ROSE is a 2018 tank ship. The Coast Guard has recorded 9 inspections since 2020, most recently in August 2024, along with 7 deficiencies.

Records from 2020 to 2024. Most recent: inspection, 15 August 2024.

Built
2018
Last inspected
15 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 August 2024
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2020–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9779238
1554801
Flag
BAHAMAS, THE
Maury page id
psix-1554801

Documentation record

Tonnage as PSIX records it144828 - Convention (Subpart B), Gross Ton
94145 - Dead Weight, Metric Ton
132029 - Displacement, Metric Ton
43448 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

15 August 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7982200
17 May 2024 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7907977
17 May 2024 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7915777
3 March 2023 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7643103
2 March 2022 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7401199
12 August 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7284510
28 April 2021 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7185094
26 April 2021 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7174927
10 February 2020 COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6900885

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2024 Resolved
The machinery, boilers, and other presure vesels, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed portable ventilation ducting was taped to fixed engine room ventilation directing cooling air to the electric motors driving the boiler feed pumps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 11 June 2024
Resolution: Class report attested to proper functionality of main water feed pump without forced ventilation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 17 May 2024 Resolved
Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at regular intervals. Suitable equipment and span gas for thsi purpose should be carried on board. Where practicable, permanent connections for such equipment should be fitted. Span gas on board vessel is not appropriate for the fixed continuous gas detection system. The 60% alarm and shutdown required for the gas as fuel system can not be tested with the span gas that is on board. 74 SOLAS (14 CONS) VII/13.1 IGC CODE 13.6.6
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 June 2024
Resolved 15 August 2024
Resolution: Vessel provided a Class Report attesting to rectification of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 April 2021 Resolved
Whenever a defect is discovered, either of which affects the safety or efficiency, or other equipment, the master or owner of the ship should report at the earliest opportunity to the administration, the nominated survyor or recognized organization who should cause investigations to be initiated. Following high pressure incident, high duty compressor #1 automatically shut down during cooldown operations. Provide documentation from class attesting to the proper operation of the #1 high duty compressor. 74SOLAS(14) VII/13; IGC (1993) 1.5.3.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2021
Resolution: Received class survey report attesting to deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 April 2021 Resolved
Every company should develop, implement, and maintain a safety management system. Vessel's safety management system requires the amount of vapour released to atmosphere which can be measured, shall be recoreded. Vessel is not equipped with a means of measuring the amount of vapor released. 74SOLAS(14) IX/3; ISM Code 1.4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2021
Resolution: Received class surey report attesting to defiency
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 April 2021 Resolved
The master shall ensure that the cargo pressureand temperature control system is operating and that venting of cargo is unnecessary except under emergency conditions. Vessel vented to atmostphere three times during cooldown operations.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 26 April 2021 Resolved
12199 - Other (tankers) - Pressure relief valves should be set and sealed by a competent authority acceptable to the administration and a record of this action, including the values of set pressure, should be retained aboard the ship. Tank #1 pressure relief valve seals were found broken. Ship's log indicate seal has been broken since September 2020. SOLAS(2014)/CH.VII, Reg 13. IGCC 1993, 8.2.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2021
Resolution: Received class surey report attesting to defiency
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 April 2021 Resolved
06199 - Others (cargo) - A master gas valve that can be closed from within the machinery space should be provided within the cargo area. The valve should be arranged so as to close automatically if leakage of gas is detected or loss of ventilation for the duct or casing or loss of pressurization of the double-wall gas fuel piping occurs. Master gas valve failed to close. Crew adjusted valve. Retested satisfactory. SOLAS(2014)/CH.VII, Reg 13 IGCC 1993, 16.3.7
Action required: 10 - Deficiency Rectified
Due 26 April 2021
Resolved 26 April 2021
Resolution: Witnessed Operation of MGV by 60% LEL after crew performed maintenance

Ownership record