G H CYCLEBOAT

G H CYCLEBOAT is a 2019 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2019, most recently in July 2026, along with 18 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 29 July 2026.

Built
2019
Last inspected
29 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 July 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1554806
Flag
UNITED STATES
Maury page id
psix-1554806

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

29 July 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8449445
9 October 2025 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8250126
26 August 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8203029
11 June 2024 COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7922477
28 May 2024 Hull Examination
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7921406
14 September 2023 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7790799
12 September 2022 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7556861
30 August 2021 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7300251
3 September 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7062280
12 June 2019 Administrative Inspection · Initial Certification
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6712348
20 May 2019 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6690201
20 May 2019 Construction Oversight · Simplified Stability Test · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6697067

Deficiency record · 18

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 August 2025 Resolved
A vessel on an LBS route requires 3 red and 3 orange hand flares. Vessel had on board 1 flare.
Action required: 10 - Deficiency Rectified
Due 27 August 2025
Resolved 27 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2025 Resolved
Portable FF extinguishers must be serviced annually by a qualified servicing facility. FF had no tags showing evidence of servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: Serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2025 Resolved
Vessel must have on board (3) 2.5 gal buckets marked "FIRE BUCKET". Vessel did not have equipment.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: Buckets on board vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 August 2025 Resolved
Each ring buoy must be marked with vessel's name. Marking is deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: Ring Buoy properly marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025 Resolved
Flexible hose for vital systems may be installed with (2) hose clamps. Fuel line from top of fuel tank had no clamps.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 29 August 2025
Resolution: Hose clamps installed sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 August 2025 Resolved
The master shall ensure all crewmembers are familiar with duties to recover persons who have fallen overboard. Vessel did not have crewmember on board to demonstrate MOB drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: MOB and fire drill completed. Sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 August 2025 Resolved
Waste receptacles must be constructed of non-combustible material with no openings in sides or bottom. Trash can had no lid.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: Adequate receptacles on board
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 27 August 2025 Resolved
Marine employers must establish programs for the chemical testing of dangerous drugs. Owner counldn't provide evidence of crewmembers in consortium for random testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 29 August 2025
Resolution: Owner provided evidence of good standing in consortium with crewmembers subject to random testing.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 August 2025 Resolved
Master of the vessel shall determine if alcohol was directly involved in a casualty. No alcohol testing strips were on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 26 September 2025
Resolution: Strips on board vessel
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 August 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2025
Resolved 27 August 2025
Resolution: Completed annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 September 2021 Resolved
COI was not posted or readily available for viewing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
Resolution: Provided waterproof sleeve to keep COI onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 September 2021 Resolved
Stability letter was not posted or readily available for viewing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
Resolution: Provided waterproof envelope to store onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2021 Resolved
Portable fire extinguisher was not mounted in required location.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
Resolution: Mounted portable extinguisher at operating station
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 September 2021 Resolved
Provide record of fire, abandon ship, and man overboard drills.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2021 Resolved
Provide satisfactory evidence of required fire extinguisher servicing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2021 Resolved
Passenger count record not readily available.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 September 2021 Resolved
Portable lights were not on board as required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 May 2019 Resolved
Vessel's new owner will be required to complete a "new-to-zone" inspection once the vessel is delivered to its new OCMI zone. The attached CG-835, and the associated worklist, will need to be completed to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 5 June 2019
Resolution: Conducted new to zone initial COI, New construction delivery list items cleared.