BERGE DANUTA is a 2000 tank ship. The Coast Guard has recorded 17 inspections since 2002, most recently in June 2008, along with 2 deficiencies and 9 operational controls.

Records from 2002 to 2008. Most recent: operational control imposed, 22 June 2008.

Built
2000
Last inspected
22 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9193721 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-15549

Inspections, by type

…with no type recorded8
Years with a record 6 calendar years (2002–2008)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it49288 - Convention (Subpart B), Gross Ton
49288 - Simplified, Gross Ton
56824 - Dead Weight, Ton
79090 - Displacement, Ton
14787 - Convention (Subpart B), Net Ton
14787 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

22 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3244215
22 June 2008 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3244266
2 March 2007 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2880879
28 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2879549
27 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2727087
21 June 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2686738
16 April 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2625742
6 February 2006 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2580199
24 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2439308
10 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2386264
20 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2339748
4 February 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2286940
3 February 2005 COC-GAS Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2287884
25 February 2004 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2006319
25 February 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2015668
14 July 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1646464
13 July 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1645187

Deficiency record · 2

Communications › Radio Communications › VHF Radiotelephone
Issued 22 June 2008 Resolved
Vessels MF/HF Radio installation is inoperable due to a lightning strike.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Received tech report attesting to proper operation of MF/HF Radio and installation of 120v 3 prong receptacle. OPCON cleared.
Engineering
Issued 25 February 2004 Resolved
Air compressor has not been serviced by expert. Prior to next U.S. port after sailing foreign, provide service report for air compressor as per IGC 14.2.6.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 February 2004
Resolution: 27 Feb 2004: Received faxed service report from Unitor attesting that air compressor has been serviced by expert as per IGC 14.2.6. J. BUTWID, [name withheld]

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.