M & M 101 is a 1977 offshore supply vessel. The Coast Guard has recorded 25 inspections since 1990, most recently in April 2009, along with 38 deficiencies.

Records from 1990 to 2009. Most recent: inspection, 27 April 2009.

Built
1977
Last inspected
27 April 2009
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA8411
155584
Flag
UNITED STATES
366854060, 367009060 (licence lapsed)
Maury page id
psix-155584

Inspections, by type

Years with a record 17 calendar years (1990–2009)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)42.1 ft × 20.0 ft × 5.5 ft
Registered tonnagegross 40 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORTS INC · HARVEY, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Net Ton
40 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCP7365MMSI 367009060 · cancelled · compulsorily equipped · granted 5 November 2014, cancelled 16 December 2014 · licensed under a name not among this hull’s recorded names (not shown)
WDA8411MMSI 366854060 · expired · compulsorily equipped · granted 24 May 2002, cancelled 28 July 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

27 April 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3462276
28 January 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3138099
20 December 2007 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3109169
15 November 2005 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2535149
25 August 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2474425
5 August 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2155707
27 May 2004 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2079724
12 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2005568
22 May 2002 COI Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1619300
18 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818101
7 September 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381659
25 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885709
24 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473410
11 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796089
20 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364429
20 August 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405953
13 August 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088898
2 October 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882991
10 August 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357289
12 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466360
5 October 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849994
3 August 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431252
10 August 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422175
26 August 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939643
10 August 1990 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228212

Deficiency record · 38

Electrical › Electric Supply System (service) › Cable
Issued 20 December 2007 Resolved
Replace 1" electrical bundle in way of starters on both main engines.
Action required: 705 - Other - as specified
Due 26 January 2008
Resolved 29 January 2008
Resolution: Bundle replaced and secured with wire ties.
Stability › Severe Wind/Roll › General
Issued 20 December 2007 Resolved
Install level alarm in accordance with NVIC 8-91.
Action required: 705 - Other - as specified
Due 26 January 2008
Resolved 29 January 2008
Resolution: Level alarm installed and operating properly.
Lifesaving › Rescue Boat › Markings
Issued 26 August 2005 Resolved
Replace the retro tape on the rescue boat.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: Retro tape was replaced on the rescue boat.
Lifesaving › Lifeboat › Markings
Issued 26 August 2005 Resolved
Mark the lifeboat with the capacity in number of people, and relabel with the name of the vessel.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: Lifeboat was properly marked.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 August 2005 Resolved
Clean the standing oil and grime out of the bilges in the engine room.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: Standing oil and grime have been removed from the engine room.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 August 2005 Resolved
Restock first aid kit. There was no asprin in the kit. This is a required item.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: First aid kit was re-stocked.
Engineering › Lubricating Oil Service System › Pump
Issued 26 August 2005 Resolved
Repair a hydraulic leak on the machinery on the stern leg tower.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: Hydraulic leak was repaired.
Engineering › Lubricating Oil Service System › Hose
Issued 26 August 2005 Resolved
Replace a corroded hydraulic line and fastener on the port bow leg tower.
Action required: 705 - Other - as specified
Due 25 September 2005
Resolved 1 December 2005
Resolution: Hydraulic line was replaced and found satisfactory.
Stability › Weathertight Integrity › General
Issued 5 August 2004 Resolved
Replace glass in aft cabin.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Glass replaced.
Stability › Watertight Integrity › General
Issued 5 August 2004 Resolved
Weld all holes in superstructure. Pull out silicone and bolts that are not being utilized.
Due 6 September 2004
Resolved 9 August 2004
Resolution: All holes rewelded.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 August 2004 Resolved
Free up engineroom emergency escape hatch. Prove proper operation.
Due 13 August 2004
Resolved 9 August 2004
Resolution: Hatch freed up, operated properly.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 August 2004 Resolved
Properly mark emergency stove disconnect.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Properly marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 August 2004 Resolved
Stencil name of vsl and homeport on both liferings.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Name installed on liferings.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 August 2004 Resolved
Prove proper weight test of crane as per 46 CFR 107.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Crane weight tested.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 5 August 2004 Resolved
Replace oil soaked lagging on hydraulic pump.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Lagging replaced.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 August 2004 Resolved
Prove engineroom soft patches are watertight. Ensure all other areas of engineroom overhead are sealed.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Soft patches resealed.
Electrical › Lighting (service) › Conductor
Issued 5 August 2004 Resolved
Make all electrical connections in the engineroom pressure type.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Pressure type installed.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 5 August 2004 Resolved
Repair oil leaks on generator.
Due 6 September 2004
Resolved 9 August 2004
Resolution: New gasket installed.
Navigation › Piloting/Steering › Marine Charts
Issued 5 August 2004 Resolved
Prove charts are provided for the vessel operating area and are corrected.
Due 6 September 2004
Resolved 9 August 2004
Resolution: Charts obtained.
Navigation › Piloting/Steering
Issued 12 February 2004 Resolved
PROVIDE CURRENT COPIES OF NAVIGATIONAL RULES, LIGHT LIST AND COAST PILOT. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Documentation › Manuals/Policy Documentation
Issued 12 February 2004 Resolved
PROVIDE APPROVED OPERATIONS MANUAL. LEGACY COMPONENT DESC: OPERATIONS MANUAL
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Fire Fighting › Ventilation Systems
Issued 12 February 2004 Resolved
REPAIR BOTH ENGINE ROOM VENT CLOSURES. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Engineering
Issued 12 February 2004 Resolved
RENEW TWO HYDRAULIC FLEXIBLE HOSES. LEGACY COMPONENT DESC: HYDRAULIC SYSTEM
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Operations/Management › Equipment Service/Testing
Issued 12 February 2004 Resolved
CONDUCT CRANE TEST. LEGACY COMPONENT DESC: CRANE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2004
Resolved 12 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 February 2004 Resolved
RENEW ALL FUEL OIL FLEXIBLE HOSES ON BOTH MAIN ENGINES AND BOTH GENERATORS WITH SAE J-1942 HOSE. LEGACY COMPONENT DESC: FLEXIBLE HOSES
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 12 February 2004
Construction/Loadline › Hull
Issued 12 February 2004 Resolved
REPAIR SMALL HOLE IN FORWARD ENGINE ROOM BULKHEAD. LEGACY COMPONENT DESC: WATER TIGHT BULKHEAD
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Lifesaving › Lifebuoys
Issued 12 February 2004 Resolved
RENEW BOTH PORT AND STARBOARD MAIN DECK LIFE RINGS. LEGACY COMPONENT DESC: CONDITION
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Lifesaving › Buoyant Apparatus
Issued 12 February 2004 Resolved
MAKE LIFE FLOATS FLOAT FREE AND TETHER PADDLES TO LIFE FLOATS. LEGACY COMPONENT DESC: STOWAGE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 February 2004 Resolved
PROVIDE AND POST LIFE JACKET DONNING PLACARD. LEGACY COMPONENT DESC: DONNING PLACARD
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Communications › Radio Communications
Issued 12 February 2004 Resolved
PROVIDE EPIRB REGISTRATION. LEGACY COMPONENT DESC: EPIRB
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 12 February 2004
Fire Fighting › Fire Pumps
Issued 12 February 2004 Resolved
DEMONSTRATE 60 PSI ON FIRE PUMP. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 February 2004 Resolved
SERVICE ONE DRY CHEMICAL FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2004
Resolved 12 February 2004
Construction/Loadline › Markings
Issued 22 May 2002 Resolved
Mark the name of vessel permanently affixed to the vessel. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Unknown
Due 22 June 2002
Resolved 3 June 2002
Resolution: Cleared by J. D. HILL, [name withheld]
Electrical
Issued 22 May 2002 Resolved
Bundle and retain all wires under steering/Radio space.
Condition: Design Flaw
Due 22 June 2002
Resolved 7 June 2002
Resolution: CLEARED BY J. D. HILL AT MSU HOUMA
Fire Fighting › Fire Hydrants
Issued 22 May 2002 Resolved
Place "L" fittings on all fire hydrants. LEGACY COMPONENT DESC: Location/Position
Condition: Design Flaw
Due 10 June 2002
Resolved 7 June 2002
Resolution: CLEARED BY J. D. HILL, CWO AT MSU HOUMA
Unknown
Issued 10 August 1990 Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 10 August 1990
Resolved 10 August 1990
Unknown
Issued 10 August 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46CFR109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 10 August 1990
Resolved 10 August 1990
Unknown
Issued 10 August 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 10 August 1990
Resolved 10 August 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.