PROGAS ODYSSEY is a 2013 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in April 2021, along with 2 deficiencies and 2 operational controls.

Records from 2019 to 2021. Most recent: inspection, 23 April 2021.

Built
2013
Last inspected
23 April 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 April 2021
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2019–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9545211
1558441
Flag
LIBERIA
Maury page id
psix-1558441

Documentation record

Tonnage as PSIX records it9160 - Convention (Subpart B), Gross Ton
2748 - Convention (Subpart B), Net Ton
10127 - Dead Weight, Metric Ton
15330 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

23 April 2021 PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7177465
15 November 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7095386
5 May 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6948786
25 April 2020 Administrative Inspection · COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6941009
11 August 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6779319
10 June 2019 COC-GAS Renew · Administrative Inspection · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6703647
10 June 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727893
7 June 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6706741
7 June 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6706752

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2020 Resolved
On ships carrying flammable or toxic products or both, a water spray system should be installed to cover exposed on deck storage vessels. Upon activation of system, PSCOs observed no water output from all nozzles over deck tank. 1993 IGC Code 11.3.1.2
Action required: 10 - Deficiency Rectified
Resolved 25 April 2020
Resolution: Crew flushed forward piping of system and restores proper coverage of the deck tank.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 10 June 2019 Resolved
when testing fixed gas detection system with 50% LEL propane from the air lock, the gas detection read out panel stabilized at 30% LEL. Crew then tested locally from the gas detection cabinet with 50% LEL propane & it again stabilized at 30% LEL from the read out. PSCOs witnessed recalibration of gas detector but was unable to carry out proper testing in the presence of PSCOs due to running out of gas. Crew must show proper testing of fixed gas detection and have appropriate amount of test gas onboard. 74SOLAS(14) VII/13.1, IGS 93/13.6.10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2019
Resolution: Vessel submitted Class NKK report attesting to satisfactory repairs and recalibration by shore technician.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.