Records from 1990 to 2004. Most recent: inspection, 29 April 2004.
Inspection history · 17
29 April 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2055558
25 June 2002
Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1636047
25 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1636282
20 February 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489127
8 August 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429404
25 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404823
22 June 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428972
31 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396772
4 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383264
14 August 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182565
24 July 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1190563
16 June 1995
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430058
6 February 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835341
11 March 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439480
7 October 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 933963
20 April 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1269864
18 September 1990
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906348
Operations/Management
Issued 25 June 2002
Resolved
Prior to movement of vessel contact MSO New Orleans Inspection Department to advise of intentions of movement and coordinate C.G. Marine Inspection prior to Movement.
Due 25 June 2002
Resolved 27 June 2002
Lifesaving › Lifebuoys
Issued 25 February 2002
Resolved
Replace missing retro reflective. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2002
Resolution: Missing retro replaced.
Lifesaving
Issued 25 August 1999
Resolved
Demonstate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements for Offshore Supply Vessels" dated 12NOV98 to thesatisfaction of the attending Marine Inspector.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Accommodation/Occupational Safety
Issued 16 June 1995
Resolved
MAKE PERMANENT REPAIRS TO FRESH WATER SUPPLY LINE TO HOUSE/ACCCOMODATION SPACE.
Condition: Unknown
Due 16 July 1995
Resolved 29 June 1995
Construction/Loadline
Issued 16 June 1995
Resolved
MAKE ENGINE ROOM ESCAPE SCUTTLE OPERATIONAL AND WATERTIGHT
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Electrical
Issued 16 June 1995
Resolved
REPLACE WASTED JUNCTION BOXES IN ENGINE ROOM AS MARKED
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Electrical
Issued 16 June 1995
Resolved
REPAIR OR REPLACE 12 VOLT EMERGENCY LIGHTING SYSTEM SERVING ENGINE ROOM ANDWHEEL HOUSE
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Electrical
Issued 16 June 1995
Resolved
REPLACE SECTIONS OF WASTED ARMORED CABLE IN ENGINE ROOM AS MARKED
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Construction/Loadline
Issued 16 June 1995
Resolved
PROVIDE PLAN FOR REPAIRING/REPLACING WASTED SECTIONS OF HOUSE STRUCTURE
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 18 September 1990
Resolved
SUBMIT AN OPERATING MANUAL TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Documentation
Issued 18 September 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Documentation
Issued 18 September 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990