Records from 2019 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 25
15 June 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8405581
27 April 2026
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8356876
4 February 2026
Vessel Attendance · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8306284
9 December 2025
Damage Survey · Vessel Attendance · Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8279996
24 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8099579
24 January 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8056771
17 October 2024
Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8020223
17 October 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8027915
21 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7881075
7 November 2023
Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7821512
20 September 2023
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7796753
23 May 2023
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7701849
19 April 2023
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7666724
13 February 2023
Administrative Inspection · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7629195
6 February 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7643361
20 January 2023
Exemption · Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7624714
5 December 2022
MARPOL Annex IV Survey · Load Line/Change of Employment · MARPOL Annex VI Survey · Examination of Repairs · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7605169
10 June 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7473720
5 November 2021
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7346029
13 July 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7255539
8 July 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7250113
7 July 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7249852
19 November 2020
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092138
29 June 2020
Deadweight Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6999523
19 April 2019
Initial Construction-Excluding Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7017140
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 June 2026
No resolution recorded
Combustibles and other foreign materials are not allowed within ventilation ducts. However, metal piping and electrical wiring installed in a metal protective enclosure may be installed within ventilation ducts, provided that the piping or the wiring does not interfere with the operation of fire dampers. STBD aft ER manual fire damper has wiring run through it that inerferes with the operation of the damper.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 May 2025
Resolved
Vessel does not meet the requirements of 46CFR116.500(b). Two required means of escape must be widely separated and if possible, at opposite ends of the space to minimize the possibility of one incident blocking both escapes. Escape routes to areas of safe refuge/embarkation areas from decks 2-3 require entering the center stairwell which is open vertically from the main deck to deck five, the forward and aft stairs do not provide a continuous link between the upper and lower decks, occupants in spaces on either side of the discontinuity are entirely reliant on the central stairway to escape and would become trapped if the central stair were to be lost due to smoke/fire. Provide permanent second means of escape routes from all decks that comply with the requirements found in 46 CFR 116.500, 46 CFR 116.510 (b)(1), 46 CFR 122.606 and meets the definition of a means of escape in 46 CFR 114.400. Submit plans for modifications to the vessel’s construction to the Marine Safety Center for approval prior to modifying the general arrangement and structural fire protection of the vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 June 2025
Resolved 12 March 2026
Resolution: Plans for modification to the vessels emergency routes, installation of emergency egress ladders, were submitted to and approved by MSC/OCMI. All modifications were completed to vessel and verified by Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 May 2025
Resolved
The vessel’s current arrangement does not meet the requirements of 46 CFR 116.500(b), which requires that each space accessible to passengers or used by crew must have two means of escape to either an area of refuge or an embarkation station. Based on limitations identified during onboard review and drill observation, the vessel’s existing layout and evacuation plan do not provide compliant secondary escape routes from several decks when the central stair tower is compromised.
The operator shall submit to the local OCMI, for review and approval, a comprehensive proposal that addresses both:
1. A revised or supplemental Emergency Evacuation Plan (EEP) that includes:
- A risk assessment identifying limitations in current escape routes and casualty scenarios;
- Alternative procedures for evacuation to areas of refuge or embarkation stations without reliance on the central stair tower; and
- Updated escape hatch and emergency exit markings in accordance with 46 CFR 122.606;
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2025
Resolved 12 March 2026
Resolution: Plans for modification to the vessels emergency routes, installation of emergency egress ladders, were submitted to and approved by MSC/OCMI. All modifications were completed to vessel and verified by Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel reported a failure of Port Azimuth Thruster that resulted in the vessel grounding at MM 289 of Columbia River. Prior to movement, vessel shall provide diagnosis of what caused the Port Azimuth Thruster to fail, evidence of permanent repair and inspection of structural integrity by CG Marine Inspectors.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 October 2024
Resolved 17 October 2024
Resolution: MI's attended VSL, obtained play by play of the events leading up to the grounding. Discovered it was unintentional human error, the Z drive was accidentally put into NFU mode without realization. No damage was found during abreviated ISE. See narrative.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 April 2024
Resolved
Fire dampers must be...marked with red letters...stating "VENTILATION FIRE DAMPER." Fire dampers in dining area were missing markings. Mark fire dampers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: Photograph provided of marked dampers.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 April 2024
Resolved
Penetrations in A-Class fire control boundaries for electrical cables...must be constructed to prevent the passage of smoke and flame for one hour. Two cable runs in engine room overhead on the forward port side were unsealed against passage of smoke and flame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: Photograph provided of sealed cable runs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 April 2024
Resolved
Every vessel must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. Vessel's Safety Radio Telephony Certificate not on board. Provide certificate. 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: Certificate provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 April 2023
Resolved
Penetrations in B-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame for 30 minutes. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Coaxial cable for televisions are installed through open faceplates compromising the integrity of the "B" class fire boundary between staterooms. Provide proper cable transit through the bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 23 May 2023
Resolution: Received e-mail and photos showing completed installation of proper cable tv cable transitions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 February 2023
Resolved
Each vessel must be provided with bilge pumps in accordance with 56.50-55(a) in subchapter F of chapter 46. Crew was unable to demonstrate satisfactory bilge pumping throughout entire system. Demonstrate required dewatering of all spaces with bilge suction to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 February 2023
Resolved 21 February 2023
Resolution: Verified operation of bilge system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency lighting did not activate upon vessel’s loss of power. Effect repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 February 2023
Resolved 21 February 2023
Resolution: Verified proper operation of emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 February 2023
Resolved
If installed, a hold back mechanism for a door in a stairtower, stairway, and main vertical zone bulkhead must allow the door to be released upon disruption of the power system. Holdbacks on multiple doors did not release upon vessel’s loss of power. Effect repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2023
Resolved 23 August 2023
Resolution: Sector SF CID authorized existing arrangement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 February 2023
Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must be of the self-closing type capable of closing against a 3.5 list of the vessel. Vessel’s Class A doors in the following locations does not self-close; 4th deck stbd forward door to lounge, 4th deck aft lounge port side door, 4th deck port side door near atrium, 3rd deck port door before bridge, 2nd deck aft door leading to stern. Effect repairs and make operational to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: Verified proper closure of identified doors.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 13 February 2023
Resolved
Nontank vessels subject to this subpart may not continue to operate on the navigable waters of the United States if the vessel is not operating in compliance with the submitted VRP. Records of required training, drills, and exercises were not available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: Verified NTVRP records.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 February 2023
Resolved
Windows or air ports in A-Class bulkheads must be fitted with frames of steel or equivalent material. Glazing beads or angles of steel or equivalent material must be installed to hold glass in place in windows or air ports in a fire control boundary in event of a fire. 2nd deck window forward-lounge to forward deck missing steel clips. Install clips to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: Verified clips properly installed on windows.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
Electrical equipment used in location normally exposed to splashing, water washdown, or other wet conditions within a galley, a laundry, or a public washroom or toilet room that has a bath or shower must be dripproof. Electrical switch box in FWD peak is shorted out due to water intrusion. Effect repairs to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: Verified repairs to electrical box.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 February 2023
Resolved
Each survival craft required on a vessel by this part must be approved under approval series 160.010 or other standard specified by the Commandant. Inflatable Buoyant apparatuses are missing survival craft placards. Install placards to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: Verified placards in place.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 13 February 2023
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Defibrillators throughout accommodation spaces are expired. Ensure equipment is renewed or replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified replacement of defibrillators.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 February 2023
Resolved
A vessel of more than 19.8 meters (65 feet) in length with overnight accommodations for more than 49 passengers must comply with the requirements of 78.13 in subchapter H of this chapter in regard to the content of a station bill, the duties of the crew, emergency signals, an emergency squad, and instructions. Station bill does not reflect who is responsible for launching IBAs. Update station bill to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified updates to station bill.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 February 2023
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and general description of the drill scenario and training topics. Fire drills are not logged IAW regulations. Log fire drills to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified drills/training properly logged.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
On vessels described by 46 CFR 114.110(e), flammable items not covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel does not have a plan in place for use of potentially hazardous items. Provide plan to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified details for hazardous items plan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by, or originating in electrical equipment, and electrical shock. Numerous dead-end wires were found under pilot house main console. Effect repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified proper termination of dead end wires.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 13 February 2023
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel’s preventative logs have numerous entries for expired items with no action taken. Conduct inspection and maintenance and update logs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2023
Resolved 21 February 2023
Resolution: Verified updates to maintenance logs.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 February 2023
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline, such as a lazarette. Bilge high level alarm in the FWD peak was inoperable. Bilge high level sensor in FWD peak replaced, operational test satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 February 2023
Resolved 13 February 2023
Resolution: Crew corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 February 2023
Resolved
Passageways and stairway enclosures shall contain only fire resistant furnishings. In addition, all upholstered chairs, sofas, etc., in these areas, shall be tested and meet the requirements in UL 1056 or have padding and upholstery of approved fire resistant materials. Stairway enclosure found with multiple furnishings which were not proven to be fire resistant. Furnishings removed from stairway enclosure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 February 2023
Resolved 13 February 2023
Resolution: Crew removed furnishings.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 February 2023
Resolved
Bulkheads and decks must be classed as A-60, A-30, A-15, A-0, B-15, B-0, C, or C’ based on the requirements in this section. Install of IBA’s on upper weather deck change the space designation from a 13 (open deck) to a 4 (embarkation station) and as such requires an A-15 deck boundary. Relocate IBA’s to suitable location with OCMI concurrence or ensure proper fire control boundary is met.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 21 February 2023
Resolution: OCMI accepted existing arrangement.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 November 2020
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway.
VSl was not unable to conduct a fire drill, a underway man overboard drill, and sea trials due to limited crew availability.
VSL shall not carry passengers until satisfactory fire,underway man overboard drills and sea trials are completed for the attending MI.
46 CFR 115.404(a)
701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2021
Resolution: Witnessed an underway man overboard drill
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2020
Resolved
Double doors capable of independent operation and latching may have a clearance between the doors of not more than 3.2 millimeters (0.125 inches).
MI observed numerous Class A fire double doors that had gaps larger than .125 inches.
Vessel is required the fix/adjust the doors within the allowable gap. Vessel is restricted prior to carrying passengers until observed by an attending MI.
46 CFR 116.435 (b)(5)(i)
701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2021
Resolution: All fire doors were correctly adjusted.