Records from 2019 to 2026. Most recent: inspection, 23 February 2026.
Documentation record
Registered dimensions (L × B × D)37.0 ft × 14.0 ft × 5.8 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAZORHEAD ALUMINUM BOATS LLC · NEW IBERIA, LA, UNITED STATES · built 2019
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portNAPLES, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
23 February 2026
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8311379
9 December 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8270273
14 January 2025
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8064252
13 September 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8002185
22 April 2024
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7899285
29 January 2024
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7857045
27 April 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7673019
12 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575742
6 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7442923
11 January 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7378035
20 April 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7178108
6 January 2020
Administrative Inspection · Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6883227
1 June 2019
Simplified Stability Test · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6814258
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 April 2024
Resolved
Each vessel certificated to operate on an oceans route in warm water must either: (1) Be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board; or (2) Be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board.
The life float exterior, grab lines, grab line and interior netting connection points, and paddles are dry rotted and cracking. The life float and paddles are not in serviceable condition and must be replaced.
The vessel is limited to not more than three (3) miles from land and not more than twenty (20) miles from a harbor of safe refuge until rectified.
46CFR180.202(b)
Action required: 705 - Other - as specified
Due 22 April 2024
Resolved 23 April 2024
Resolution: The vessel installed a new 15 pax capacity life float which will accommodate at least 100% of the total number of persons permitted on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
The visual alarm for the following compartments are non-operable: 1, 5, and 10.
46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2024
Resolved 30 April 2024
Resolution: A visual and audible alarm is now provided at the operating station to indicate a high water level in all compartments.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2022
Resolved
Your vessel must undergo an annual inspection within the 03 months before or after each anniversary date.
Vessel's annual inspection date was overdue on 05MAY2022.
Vessel is not to carry passengers until a satisfactory annual inspection is completed.
46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2022
Resolved 12 May 2022
Resolution: Completed satisfactory annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 April 2021
Resolved
Watertight bulkhead cable penetrations on starboard side through bulkheads 4 and 7 are not properly sealed. Seal penetrations with approved epoxy resin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 28 April 2021
Resolution: Received e-mail with photos of fire stop placed in bulkhead penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Double clamp fuel lines at connections to fuel filters.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 20 April 2021
Resolution: Received photos via e-mail after inspection of double clamped fuel lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2021
Resolved
Provide corrosion resistant clip for ring buoy light attachment to ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 20 April 2021
Resolution: Received photos via e-mail of new clip for ring buoy light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 April 2021
Resolved
Provide current Light List.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 20 April 2021
Resolution: Received photo after inspection of updated light list.