ROUGHNECK

ROUGHNECK is a 1978 industrial vessel. The Coast Guard has recorded 15 inspections since 1994, most recently in May 2022, along with 1 deficiency.

Records from 1994 to 2022. Most recent: inspection, 24 May 2022.

Built
1978
Last inspected
24 May 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYF5050
156249
Flag
UNITED STATES
—
Maury page id
psix-156249

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (1994–2022)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)45.8 ft × 20.0 ft × 6.5 ft
Registered tonnagegross 64 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC&M SHIPBUILDING COMPANY · ORANGE, TX, UNITED STATES · built 1978
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, NC
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

24 May 2022 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7459008
12 May 2022 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7449938
18 January 2022 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7381887
2 December 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7361304
17 February 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7143029
8 January 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7129045
12 August 2020 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7030823
6 December 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4201978
17 June 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 429834
4 February 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 676457
4 February 1999 Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 791720
22 April 1998 Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 790168
5 March 1998 Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1120235
8 December 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 676458
5 December 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 171356

Deficiency record · 1

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2020 Resolved
Owners and operators with only one existing towing vessel must have a valid Certificate of Inspection (COI) prior to July 20, 2020. This vessel has not obtained a valid COI in accordance with the regulations. This vessel shall be made available for a Coast Guard COI inspection, within 90 days. If an inspection is not completed prior to this date, this deficiency shall be changed to a code 60 (Rectify deficiency prior to movement) and the vessel will no longer be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 November 2020
Resolved 15 September 2020
Resolution: Vessel was granted a workboat exemption. Letter uploaded under documents

Ownership record