Records from 2019 to 2026. Most recent: inspection, 21 July 2026.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2019
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
21 July 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8447764
22 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8191566
26 September 2024
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8003490
15 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8002637
15 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8005368
27 August 2024
Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7986543
7 August 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7976179
13 October 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810161
18 July 2023
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7745630
8 February 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7634119
27 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627952
29 March 2022
Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7416637
25 February 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7402108
13 March 2020
Deadweight Survey · In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6926012
1 July 2019
Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6732567
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 September 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
46 CFR 181.610
Vessel did not have three 2 1/2 gallon buckets labeled with lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 12 October 2024
Resolution: Operator purchased correct fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024
Resolved
A vessel must carry one floating waterlight,... (2) Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip.
Vessel life ring bouy lanyard line was over 6 ft and not attached with a clip.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 12 October 2024
Resolution: Operator attached missing clip and appropriate length lanyard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024
Resolved
(A vessel must be provided with bilge pumps in accordance with Table 182.520(a)...Less than 7.9 m (26 ft)1 portable hand pump..
Vessel did not have a portable hand pump
46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 12 October 2024
Resolution: Operator purchased portable hand bilge pump.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 26 September 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159...
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include—(1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position.
Vessel did not have any mechanism to lock overboard discharge.
33 CFR 159.7 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 16 October 2024
Resolution: Operator installed securing device.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 September 2024
Resolved
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers....
No garbage placards were present.
33 CFR 151.59
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 12 October 2024
Resolution: Operator installed garbage placard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 September 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. CHAMPAGNE SHOWERS was observed operating in Biscayne Bay, FL with passengers onboard on 14SEP24.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2025
Resolution: COI was onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 September 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2024
Resolution: Deficiency is being tracked in Admin Inspection MISLE Act # 8005368.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 August 2024
Resolved
To maintain a valid Certificate of Inspection, (a) The owner or managing operator shall make the vessel available for drydock examinations, internal structural examinations, ... required by this section. (c)(1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. This vessel is overdue for its drydock and internal structural exam. Vessel cannot operate until completion of this exam and a renewal COI exam is successfully completed.
46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2025
Resolution: Clearing old outstanding deficiency. Vessel completed required DD/ISE and COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Obtain 51 adult life jackets.
46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: Operator purchased and placed onboard 51 adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 February 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Accurately mark the number of children and adult life jackets per stowage area.
46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: Witnessed life saving appliance markings for life jacket stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2023
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Corroded clip did not allow for attachment to the life bouy, repair or replace clip.
46 CFR 180.70(d)3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2023
Resolution: Clip on floating waterlight for ring buoy replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 February 2023
Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating.
46 CFR 185.402
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2023
Resolution: Operator provided proof of a licences mariner to act as Captain of vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 8 February 2023
Resolved
...ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Display garbage placards.
33 CFR 151.59(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2023
Resolution: Garbage placard placed on vessel
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Red navigation light to be replaced.
46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: Conducted satisfactory check of all navigational lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 February 2023
Resolved
Each operator shall keep the following records... MIS annual report data shall be maintained for a minimum of five years. Obtain MIS report and keep on board vessel for inspection.
46 CFR 16.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2023
Resolution: Vessel submitted MIS via email
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2023
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
46CFR176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2023
Resolution: Vessel annual inspection was conducted 8FEB2023.