Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it18386 - Convention (Subpart B), Net Ton 50513 - Dead Weight, Metric Ton 69699 - Displacement, Metric Ton 46668 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 8
23 September 2025COC-GAS Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8234653
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 1 August 2022Resolved
THE GAS DETECTION EQUIPMENT MAY BE LOCATED IN A NON HAZARDOUS SPACE PROVIDED THAT THE DETECTION EQUIPMENT ARE LOCATED IN A FULLY ENCLOSED STEEL CABINET WITH THE DOOR SEALED BY A GASKET. THE ATMOSPHERE WITHIN THE ENCLOSURE SHALL BE CONTINUOUSLY MONITORED.
PROVIDE DOCUMENTATION FROM CERTIFIED ISSUING AUTHORITY ATTESTING TO PROPER INSTALLATION AND OPERATION OF CONTINUOUS MONITORING IN THE CCR FIXED GAS DETECTION CABINET.
THE SALWICO SW2020 GAS DETECTION SYSTEM MONITORS THE ATMOSPHERE AS PART OF THE SUCTION ROTATION, NOT CONTINUOUSLY.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2022
Resolution: Vessel provided technician report stating system was serviced and class survey attesting to the rectification of the fix gas deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.