MAURY USCG vessel records
← All vessels

MANTA ANKA

MANTA ANKA is a 2013 tank ship. The Coast Guard has recorded 20 inspections since 2019, most recently in March 2026, along with 6 deficiencies and 5 operational controls.

Records from 2019 to 2026. Most recent: inspection, 23 March 2026.

Built
2013
Last inspected
23 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9666663
1573057
Flag
PANAMA
Maury page id
psix-1573057

Documentation record

Tonnage as PSIX records it7385 - Convention (Subpart B), Net Ton
28263 - Dead Weight, Metric Ton
39683 - Displacement, Metric Ton
24617 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

23 March 2026 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8330115
23 March 2026 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8343568
7 March 2026 COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8321315
14 November 2023 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7823226
4 February 2023 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7627314
16 December 2022 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7610209
16 December 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7610212
15 November 2021 PSC B · MARPOL Annex VI Survey · Administrative Inspection · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7348629
11 February 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7139300
10 November 2020 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7090196
10 November 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7093305
10 November 2020 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7093326
30 April 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6945650
30 April 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946021
30 April 2020 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946604
5 February 2020 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6903176
4 February 2020 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6984977
4 November 2019 Ballast Water Examination · ISM Oversight · ISPS II Exam · Deficiency Check · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6844050
4 November 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6850119
1 November 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6847441

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 March 2026 Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. PSCO observed multiple light fixtures in the hazardous zone on deck with missing or broken ground wires. Additionally, PSCO observed holes in electrical junction boxes located at cargo tank #3, indepedent cargo tank on starboard bow, and deck fan junction box on gas freeing fan unit #1. 74SOLAS(20) VII 13.1 IGC(93) 10.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2026
Resolution: Cleared on the Spot
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 November 2020 Resolved
Airlock doors should be self-closing and without any holding back arrangements. Upon inspection, PSCO observed air lock door leading to the weatherdeck was not self-closing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 12 November 2020
Resolution: Vessel crew adjusted the airlock door self-closing device prior to the completion of the inspection. PSCO observed door closing properly with [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel lifeboat was damaged during marine casualty while the vessel was docking. Provide class report attesting to the readiness of the lifeboat and launching appliance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2020
Resolution: See attached class report.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 4 November 2019 Resolved
The system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water-spray of at least 10 l/m2 per minute for horizontal projected surfaces and 4 l/m2 per minute for vertical surfaces. The water spray system coverage was not adequate. The #1 cargo tank had no coverage, the deck tank had 50% coverage, and the port and starboard manifolds only had 66% coverage. 74 SOLAS (2014) VII/12 IGC Code (1993) 11.3.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 November 2019
Resolution: Witnessed satisfactory operation of deck water spray.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 4 November 2019 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with any additional requirements which may be established by the company. As identified in deficiency 02, objective evidence exists that the vessel's deck spray is not being maintained in conformity with the relevant rules (IGC Code). In review of SMS procedures relating to deck spray, on board maintenance records are contradictory to the condition of the system as observed by the [name withheld], the crew was unable to perform, follow, present, or explain any procedures regarding the use, operation, and testing of either of the vessel's two independent and mechanically different fixed gas detection systems. An internal audit and review of vessel's SMS specifically focused on the operation, maintenance, and testing of cargo safety systems, to include at a minimum fixed gas detection and deck spray, is required within 90 days. 74 SOLAS (14) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2020
Resolved 4 February 2020
Resolution: Company Provided documentation addressing all issues of concern (see Documents)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 November 2019 Resolved
Where electrical equipment is installed in gas dangerous spaces or zones as provided in 10.1.4, it should be the satisfaction of the Administration and approved by the relevant authorities recognized by the Administration for operation in the flammable atmosphere concerned. PSCO identified flame-proof lighting with unapproved plug installed into the housing located in the SOPEP locker. The PSCO also identified an electrical panel in the motor room located next to the #3 compressor motor missing appropriate cable plug. 74 SOLAS (14) VII/12 IGC Code (93) 10.1.5
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2019
Resolution: Verified appropriate electrical installations were fitted.

Ownership record