Records from 2018 to 2024. Most recent: inspection, 4 October 2024.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)63.0 ft × 21.3 ft × 8.0 ft
Registered tonnagegross 24 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT E DERECKTOR INC · MAMARONECK, NY, UNITED STATES · built 2019
Hull materialAluminum
PropulsionDiesel Electric
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portNORWALK, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 23 July 2019
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
8 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 8
4 October 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8014479
7 September 2023
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7787011
25 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7681085
14 October 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7577227
26 July 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7269659
7 July 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7239395
27 October 2020
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7498415
26 June 2018
COI Inspection · Construction Oversight · Plan Review "T" Boat · Welding Related Inspections Qualification Testing · Deadweight Survey · Administrative Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6777746
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 May 2023
Resolved
At each inspection, the marine inspector may require emergency drills to be conducted. Vessel did not have adequate manning to conduct drills or get underway. No carriage of passengers is permitted until rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Conducted MOB and fire drill while underway.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 May 2023
Resolved
A hatch cover must be attached by hinges or captive chains to prevent its loss. The fore peak hatch cover did not have any hinges or captive chains.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Observed captive chain.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2023
Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact with energized parts. A junction box in the port tank room was missing a cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 7 September 2023
Resolution: Cover was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2023
Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wires were found in the overhead in the head.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Exposed wires were taken care of.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2023
Resolved
Submersible electric bilge pump located in port tank room does not operate in automatic mode, only in manual.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Observed operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2023
Resolved
Each life line on a life ring must have a breaking strength of 1,124 lbs. The life line on starboard life ring is deteriorated and needs replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 7 September 2023
Resolution: Observed satisfactory lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2023
Resolved
Each life ring must be approved in accordance with 46 CFR 160.050; both life rings had deteriorated grab lines that need replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Observed new liferings.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 May 2023
Resolved
Each life float shall be fitted with two paddles. All four life floats only had one paddle each.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Observed correct number of paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 May 2023
Resolved
Life floats must be approved under 46 CFR 160.027.
Color of the life float must be primarily vivid reddish orange. All four life floats were faded to a pale orange.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Lifefloats were painted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 May 2023
Resolved
The number of persons capacity must be marked on each life float. All four life floats were not marked with the capacity.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 3 August 2023
Resolution: Capacity marked.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 May 2023
Resolved
A vessel must carry a first aid kit approved under 46 CFR 160.041. The first aid kit had expired items that need replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 7 September 2023
Resolution: Expired items were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 October 2022
Resolved
Vessel is currently overdue for annual inspection. The COI anniversary date is July 6th. The window for the annual inspection ended on October 6, 2022. Vessel in not authorized to operate until an annual inspection in completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2023
Resolution: Annual inspection was conducted on 25May23.