MAURY USCG vessel records
← All vessels

FALCON II

FALCON II is a 2019 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2019, most recently in January 2026, along with 12 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 28 January 2026.

Built
2019
Last inspected
28 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 January 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1573624
Flag
UNITED STATES
Maury page id
psix-1573624

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

28 January 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285641
7 January 2025 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8059191
25 January 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7838609
26 January 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7615731
21 December 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7371172
21 January 2021 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7121331
4 November 2019 DAPI Audit · Administrative Inspection · Initial Certification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848843
10 May 2019 Plan Review "T" Boat · Simplified Stability Test · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6747276

Deficiency record · 12

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 January 2026 Resolved
Each ring life buoy must be approved in accordance with 46 CFR 160.050 or other standard approved by the Commandant. MI observed ring life buoy on board to have wasted/missing grab lines. Replace ring life buoy with approved equivalent. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 26 February 2026
Resolution: Received photo evidence via email of new approved ring life buoy on board vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2025 Resolved
A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 18Nov24 and has yet to receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued. 46CFR176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2025
Resolution: Completed COI renewal.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination on 31Oct24 and has yet to receive a drydock exam. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2025
Resolution: Completed Drydock examination.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit on board the vessel did not have a tourniquet. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2023
Resolved 20 March 2023
Resolution: Received photos of purchased tourniquets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2023
Resolved 20 March 2023
Resolution: Received photos of purchased flashlights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The fuel shut off valve is located in a difficult to access area. 46 CFR 185.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2023
Resolved 20 March 2023
Resolution: Received photo evidence of pull cable installed for fuel shut-off valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2021 Resolved
46CFR180.70(b) Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050. Vessel's ring life buoy is recreational and does not meet Coast Guard approval for commercial vessels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 27 January 2021
Resolution: Owner replaced ring life buoy with approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019 Resolved
A Vessel must carry one floating water light unless it is limited to daytime operation, in witch caser no floating water light is required. Vessel is missing floating water light and limited to daytime operation. 46CFR180.770(d)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 December 2019
Resolved 16 December 2019
Resolution: Owner / Operator purchased and installed approved water light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2019 Resolved
Vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel is missing ammonia inhalants and eye wash. 46CFR184.710
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 December 2019
Resolved 16 December 2019
Resolution: Owner / Operator purchased ammonia inhalants and eyewash.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019 Resolved
Ring life buoy must be marked with type II retroreflective material approved in accordance with 46CFR164.018. Retroreflective material on ring buoy found in wasted condition. 46CFR185.604
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 2 December 2019
Resolved 16 December 2019
Resolution: Owner / Operator replaced wasted retroreflective material with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019 Resolved
Ring life buoys must be fitted with life line. Ring life buoy missing UV protected 60ft, 5/16 inch life line.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 December 2019
Resolved 16 December 2019
Resolution: Owner / Operator purchased and installed approved lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2019 Resolved
A positive shut off valve is installed at hull penetration for submersible electric bilge pump. Vessel missing shuttoff valve at hull penetration.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 December 2019
Resolved 16 December 2019
Resolution: Owner / Operator made approved alterations.

Ownership record