Records from 2020 to 2026. Most recent: inspection, 8 June 2026.
Documentation record
Registered dimensions (L × B × D)578.1 ft × 105.6 ft × 62.7 ft
Registered tonnagegross 29,708 / net 13,729
ITC dimensions (L × B × D)578.1 ft × 105.6 ft × 62.7 ft
ITC tonnagegross 29,708 / net 13,729
BuilderHYUNDAI MIPO DOCKYARD CO LTD · ULSAN, KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsRegistry
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29708 - Convention (Subpart B), Gross Ton
50332 - Dead Weight, Ton
49999 - Displacement, Ton
13729 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 44
8 June 2026
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8395135
15 May 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8373671
15 May 2026
Type not recorded
No type recorded · Activities Europe · Activity 8406616
11 April 2026
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8350635
3 April 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8341329
20 March 2026
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 8329098
18 March 2026
Type not recorded
No type recorded · Activities Europe · Activity 8332245
4 February 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8305816
12 January 2026
Cargo Tank Internal · Internal Structural Exam
Physical examination · Activities Europe · Activity 8294598
17 December 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8285140
17 December 2025
Type not recorded
No type recorded · Activities Europe · Activity 8306389
26 September 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8241774
18 September 2025
Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8215739
26 July 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8194861
24 July 2025
Type not recorded
No type recorded · Activities Europe · Activity 8227520
3 July 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8173945
21 June 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8165004
31 March 2025
Deficiency Check
Physical examination · Activities Europe · Activity 8102345
21 February 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8082882
18 February 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8081123
25 October 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8024525
12 September 2024
MSP COI Oversight · COI Inspection
Physical examination · Activities Europe · Activity 7997490
4 September 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7995978
30 August 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7992737
20 June 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7938460
20 June 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7942797
31 January 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7858437
9 January 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7847113
8 November 2023
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7808254
30 October 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7816845
25 October 2023
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7813966
2 October 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7816852
9 August 2023
Damage Survey
Physical examination · Activities Europe · Activity 7763788
30 July 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861939
14 April 2023
Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 7668532
25 March 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7658256
24 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7656065
22 February 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7640578
5 December 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604081
1 December 2022
MSP Initial Reflag · MSP COI Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7609859
1 March 2022
COC-CHEM Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7401297
4 January 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609546
2 February 2021
COC-CHEM Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7131212
3 February 2020
PSC A · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6900574
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 May 2026
Resolved
If electrical power is normally supplied by more than one generator, provisions shall be made, for instance by load sheding, to ensure that, in case of loss of one of these generating sets, the remaining ones are kept in operation without overload to permit propulsion and steering, and to ensure the safety of the ship. Vessel self-reported that #1 Generator began load shedding, and then the #3 generator load subsequent load shed, led to vessel experiencing a loss of propulsion. Mechanical means of failure was unable to be identified. Vessel is required to submit the following to our office. Mitigation plan in case of reoccurence to ensure safety of vessel when transiting high traffic areas, Class proposal on measures to be taken while issue is diagnosed. Techreport/Class report attesting to the identification of the resulting factors that led to the loss of propulsion.
II-1/53.2.2
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 4 June 2026
Resolved 8 June 2026
Resolution: Received satisfactory survey/tech report.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 January 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Isolated pitting was found on the sump of the 4/P cargo tank. Vessel to fix prior to the completion of next drydock period to the satisfaction of class.
SOLAS (2004) I/Reg 11(a)
Action required: 705 - Other - as specified
Resolved 12 April 2026
Resolution: ABS issued finding number 426.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 21 February 2025
Resolved
The vessel failed to meet the COI requirement that all three maintenance personnel must hold the endorsement for able seaman or be substituted with a ordinary seamen with STCW endorsement for "rating forming part of a navigation watch", maximum of two (2) of these able seamen.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2025
Resolution: Received IMO crew list and MMC copies of newly reported crew. All SAT.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 September 2024
Resolved
15108- Reports of non-conf. accidents * hazardous occurrences: The company should establish procedures for the implementation of corrective action, including measures to prevent recurrence. 14JUN24 CO2 control valves were left blinded as per yard instruction. Master/CE was informed of condition to be corrected prior to sailing by technician. 17Jun24 Near miss found by vessel discovered that Main Engine Room CO2 room pilot bottlers had been disconnected. 13SEP24 MI discovered CO2 pilot bottles in Foam Room for Main Engine Room CO2 system were still disconnected, blinding the system from actuation. Vessel had not identified that both activation systems were blinded, leaving one main activation system inoperable and a danger to crew as CO2 would discharge directly into foam room/repair locker which could result in incapacitation , loss of vessel or death. Vessel is required to submit corrective action in 30 days that implements an SMS procedure for documentation of blinded systems, identifying how they were blinded, their return to working order and the verification of the process completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2024
Resolved 14 October 2024
Resolution: Vessel Submitted docuementation, meeting the requirements that proper updates were made to SMS to prevent reoccurence.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2024
Resolved
07109- Fixed fire extinguishing installation- The following functional requirements shall be met: fire-extinguishing appliances shall be readily available. Pilot bottles for the Main Engine room CO2 system were found disconnected in the foam room removing the ability to actuate from the remote station. In presence of [name withheld] engineer reattached pilot bottle fittings to return system to fully operational status.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 September 2024
Resolution: Corrected on the spot
01 - Certificates & Documentation › 012 - Crew Certificates › Application for Endorsement by flagstate
Issued 12 September 2024
Resolved
01209- Manning specified by the minimum safe manning document- Whenever a vessel is deprived of service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel [...] a report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating or OCMI within whose jurisdiction the voyage is completed. Vessel master made sailing short notification for the position of the 1st Eng from Antwerp, Belgium to Piraeus, Greece.
46 CFR 15.725
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 27 September 2024
Resolution: Vessel received new 1AE and now at safe manning level.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 27 January 2023
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the side of the ships to satisfaction of administration.
Load Line markings were not permanently marked and paint has worn off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 January 2023
Resolved
All life-saving appliances and arrangement shall comply with applicable requirements of the Code.
Markings on life saving appliances had previous hailing port.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2023
Resolved
The foam concentrates of low-expansion foam fire-extinguishing systems shall be approved by the Administration based on the guidelines adopted by the Organization.
Servicing certificates could not be provided for fixed foam when replaced in 2022.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2023
Resolved
Every boiler shall be provided with at least two means for indicating its water level, at least one of which shall be a direct reading gauge glass. Vessels gauge class was crack and provided unreliable reading.
Boiler sight glass was broken and unreadable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2023
Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products.
Electrical J box on STBD King post missing end caps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger. Vessels jacket water recirculation pump was found to be leaking excessively from its mechanical seal.
Jacket water recirc pumps mechanical seal leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 27 January 2023
Resolved
The Revised NOx Technical code 2008 shall be applied in the certification, testing and measurement procedures for the standard set forth in this regulation.
Provide EIAPP certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2023
Resolved
Every steam boiler and every unfired steam generator shall be provided with not less than two safety valves of adequate capacity. Vessels boiler had no means to verify the relief or set pressure during the relief valve test.
Could not verify relief pressure when testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 27 January 2023
Resolved
Where automated systems are provided to replace specific
personnel in the control and observation of the
engineering plant and spaces, or reduce overall crew
requirements, the arrangements must make sure that under
all sailing conditions, including maneuvering, the
safety of the vessel is equal to that of the same vessel
with the entire plant under fully attended direct manual
supervision.
Provide approved PSTP's to the satisfaction of the attending Coast Guard Marine Inspector. Complete prior to next annual inspection.
46 CFR 62.50-1
Action required: 705 - Other - as specified
Due 8 December 2023
Resolved 31 January 2024
Resolution: PSTPs approved by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2022
Resolved
The master, owner, operator, agent, or person in charge
of a vessel equipped with ballast tanks that operates in
the waters of the United States must employ one of the
following ballast water management methods:(1)Install
and operate a ballast water management system (BWMS)
that has been approved by the Coast Guard under 46 CFR
part 162.
Provide proper Operation, Maintenance and Safety Manual
(OMSM) as shown on Coast Type Approval Certificate as
well as providing correct BWMS marking (data plate) in
accordance with 46 CFR 162.060-22.
33 CFR 151.2025(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2023
Resolved 13 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 February 2020
Resolved
A FOOD RATION DESCRIBED IN PARAGRAPH 4.1.5.1.18 TOTALLING NOT LESS THAN 10,000 KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMMODATE; THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING AND BE STOWED IN A WATERTIGHT CONTAINER. PSCOS OBSERVED THAT THE STBRD LIFEBOAT FOOD RATIONS WERE NOT IN A WATERTIGHT CONTAINER.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 4 February 2020
Resolution: Vessel Master provided Administration (Flag) report stating that satisfactory watertight containers were provided to resolve the deficiency.