Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
125 - Simplified, Net Ton
156 - Simplified, Gross Ton
Maury page id
psix-1575290
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
9 December 2025Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8279453
5 December 2024Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8042743
25 October 2024Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8024543
14 December 2023Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7838942
13 December 2022Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7608376
14 September 2021Administrative Inspection · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7312699
8 August 2019Construction Oversight · Administrative Inspection · Inclining Experiment
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6822722
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2025Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Remote fuel shutoffs were not labeled.
46 CFR 143.260(e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 13 January 2026
Resolution: received pictures clearing def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2025Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The emergency exit on the engine room and above in hall space was missing required markings.
46 CFR 144.160(f)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 13 January 2026
Resolution: received pictures clearing def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2025Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. Nozzle could not produce a spray pattern.
46 CFR 142.325(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2026
Resolved 13 January 2026
Resolution: received pictures clearing def.