Records from 2019 to 2025. Most recent: inspection, 1 December 2025.
Documentation record
Registered dimensions (L × B × D)26.0 ft × 9.3 ft × 4.7 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTERN INC · BROOKLIN, ME, UNITED STATES · built 2019
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHARLOTTE HARBOR, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
1 December 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8273814
13 October 2024
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8003275
6 November 2023
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7819740
30 October 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7816509
27 March 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7656347
19 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7580277
17 November 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7352089
9 September 2021
Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7307477
22 October 2019
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6855631
9 August 2019
Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6777661
23 July 2019
Hull Examination · Construction Oversight · Plan Review "T" Boat · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6759721
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 March 2023
Resolved
Your vessel must undergo an annual inspection within the 03 months before or after each anniversary date.
Vessel's annual inspection date was overdue on 09DEC2023.
Vessel is not to carry passengers until a satisfactory annual inspection is completed.
46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 March 2023
Resolved 27 March 2023
Resolution: Completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2021
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI but must not be fewer than the minimum number required by table 181.500(b).
02 portable fire extinguishers are on board; one 10-B:C for the operating station and one 60-B:C for the machinery space. An additional 2-A extinguisher is required by the table for the accommodation space.
46 CFR 181.500(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: A-2 extinguisher installed onboard IVO stern compartment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2021
Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. Fixed gas extinguishing systems...owner must provide satisfactory evidence of required servicing.
Portable and fixed fire fighting systems have not been serviced since installation in 2019.
46 CFR 176.810(b)(1) & 46 CFR 176.810(b)(1)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: Portable and fixed Fireboy systems serviced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 September 2021
Resolved
Radio stations must have an authorization granted by the FCC.
VHF radio does not have a valid Safety Radio Certificate. Vessel restricted to 1,000 feet from shore until rectified.
47 CFR 80.405(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: Received valid Safety Radio Certificate.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 September 2021
Resolved
Inspection of ships subject to the Communications Act must have a FCC Safety Certificate.
VHF radio installation does not have a safety certificate. Vessel restricted to 1,000 feet from shore until rectified.
47 CFR 80.59
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: Received valid VHF radio certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 September 2021
Resolved
A vessel on a Lakes, Bays and Sounds route must carry: three hand red flare distress signals and three hand orange smoke distress signals.
No flares were onboard.
46 CFR 180.68(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: 6 red hand flares provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 9 September 2021
Resolved
A vessel must carry a first aid kit approved under approval series 160.041.
The first aid kit onboard did not have all of the equipment required by regulation.
46 CFR 184.710
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: First aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 September 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date:
1) Charts
2) US Coast Pilot
3) Coast Guard List List and,
4) Tide Tables
Publications on board were out of date.
46 CFR 184.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 16 September 2021
Resolution: All publications updated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 November 2019
Resolved
Obtain Electrical Plan Approval to the satisfaction of the attending Marine Inspector. (Plan currently under review at MSC).
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 13 December 2019
Resolution: Plan was approved by MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 November 2019
Resolved
Provide copy of Certificate of Documentation.
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 9 September 2021
Resolution: MSD [name withheld] confirmed active COD is onboard vessel during annual on 09SEP21.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 November 2019
Resolved
Conduct New To Zone COI Inspection with Local OCMI (Fort Meyers/Sector St. Petersburg).
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 9 September 2021
Resolution: MSD Fort Myers conducted NTZ COI Inspection.