Documentation record
Registered dimensions (L × B × D)55.0 ft × 16.0 ft × 4.8 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWCASTLE MARINE LLC · PALATKA, FL, UNITED STATES · built 2019
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
19 March 2026
Vessel Attendance · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8297850
3 February 2025
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8060528
13 August 2024
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7940450
31 January 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7845914
27 April 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7670168
26 August 2022
Examination of Repairs · Internal Structural Exam · Hull Examination · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7531436
2 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7130518
18 August 2020
Internal Structural Exam · Damage Survey · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7033053
27 February 2020
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6895277
15 October 2019
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6836493
25 July 2019
Plan Review "T" Boat · Welding Related Inspections Qualification Testing · Administrative Inspection · Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6775972
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 March 2026
Resolved
Vessels of 12 meters or more in length but less than 50 meters require an all-round light. MI observed missing all-round light. Provide all-round light.
705c: Vessel restricted to daylight operations and limited to 2nm of visibility.
33CFR83.22(b)(v)
Action required: 705 - Other - as specified
Resolved 26 March 2026
Resolution: All-round light replaced and operation was verified by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Make repair to electrical wiring in engine space running along the overhead adjacent to the starboard engine.
46CFR183.200(c)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2026
Resolved 26 March 2026
Resolution: Operator repaired torn insulation with heat shrink. Repair accepted by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 February 2025
Resolved
On a vessel greater than 26' a visual and audible alarm must be provided at the operating station. The audible alarm buzzer was not operational. Repair audible alarm to the satisfaction of the Coast Guard. Ensure each master is checking the visual display every 10 minutes until repairs is completed.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2025
Resolved 11 February 2025
Resolution: High level alarm is functioning properly. SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2025
Resolved
The name of the vessel must be clearly marked on each ring life buoy.
Vessel name was no longer legible on the ring buoy. Relabel the ring buoy in block capitol letters with the vessels name.
46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2025
Resolved 11 February 2025
Resolution: Life ring was properly labeled, SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 March 2021
Resolved
Shutoff valves must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Tank connection shutoff valve remote cable found seized and inoperable when tested. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 9 March 2021
Resolution: Cable on tank connection fuel shutoff was replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 February 2020
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Found stability letter has not been issued, notify attending MI as soon as stability letter has been received and posted.
46 CFR 176.306
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2020
Resolution: O/O posted Stability Letter on vessel as per CFR.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 February 2020
Resolved
Seats must be secured to a deck or bulkhead, found seats not secured to the deck or bulkhead. Secure seatings to the satisfaction of the attending MI.
46 CFR 177.820(d)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2020
Resolved 13 March 2020
Resolution: Cleared