Records from 2000 to 2010. Most recent: inspection, 30 December 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
30 December 2010
ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3916609
21 February 2010
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3685749
12 January 2010
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3662902
27 February 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2014463
26 February 2004
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2010108
5 February 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2000983
28 August 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1889925
15 May 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1790905
25 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1780478
4 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1768008
3 April 2003
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1766525
18 November 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1706938
30 August 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1668676
27 December 2001
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473984
20 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 189885
20 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 769544
21 October 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 639561
Electrical › Lighting (service) › Lighting Fixture
Issued 30 December 2010
Resolved
Provide explosion proof light fixture for acytelene and oxygen storage room at stern.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Explosion Proof light installed
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 December 2010
Resolved
Replace B-II Fire Extinguisher in starboard bow foscle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 30 December 2010
Resolution: Extra extinguisher on board was put in location to replace inop extinguisher.
Stability › Watertight Integrity › General
Issued 30 December 2010
Resolved
Found forward stbd side watertight door leading to hause pipe room unable to close. Door warped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Door able to be secured.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 30 December 2010
Resolved
Found CO2 system for paint locker with approximately 3" excess actuating cable which may hinder actuation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class by removing excess cable.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 December 2010
Resolved
Ensure light fixture in paint locker is explosion proof.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class.
Fire Fighting › Fire Hoses › Location
Issued 30 December 2010
Resolved
Found several fire hose stations on main deck tied in place due to hose box condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class
Stability › Weathertight Integrity › General
Issued 30 December 2010
Resolved
Replace portside shattered window at stern main deck to crew lounge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class. Temporary window installed until replacement is received.
Fire Fighting › Structural - Horizontal Zones › General
Issued 30 December 2010
Resolved
Ensure all fire doors are capable of complete closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 December 2010
Resolved
Ensure all fire extinguishers are in proper mounting brackets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2011
Resolved 4 February 2011
Resolution: Cleared by class.
Engineering › Lubricating Oil Service System › Piping
Issued 26 February 2004
Resolved
Aft steering iol leak for deck machineriy, leaking port side aft bulkhead, in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Rcvd Class report attesting to repairs
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 26 February 2004
Resolved
Improper sight glass hydrolic oil tank, starbord side in aft steering
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 21 February 2010
Electrical › Electric Generation Source (service)
Issued 26 February 2004
Resolved
Open junction box, over-head aft steering in engine room. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Rcvd fax for [name withheld] stated the item had been repaired to statisfaction.
Engineering › Steam System (main) › Piping
Issued 26 February 2004
Resolved
Steam generator was found torn apart and inoperable, with cooil leaking in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 21 February 2010
Engineering › Steam System (auxiliary)
Issued 26 February 2004
Resolved
Leak was found in forward bulkhead, steam condensor line, in engne room LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 26 February 2004
Resolution: A section of pipe was renewed and approved by class
Engineering › Freshwater Generation System
Issued 26 February 2004
Resolved
Salt water line for fresh water generator on starboard side was found leaking in engine room LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 28 February 2004
Resolution: A section of pipe from flange to flange was renewed, to satisfaction of Class as per fax dated 2 MAR 04
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 26 February 2004
Resolved
# 6 CYI MDE leaking excessively, approximately 5 gallons an hour, in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item was cleared by classification society, by fax rcvd 27 feb 04.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Lower lever escape fire door inoperable, in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 28 February 2004
Resolution: Repairs to the lowere esape fire door were made. The door now closes and latches to satisfaction of class. As per fax dated 02 MAR 04
Engineering › Sea-water System (primary cooling)
Issued 26 February 2004
Resolved
# 1 salt water pump packing gland leaking excessivly, in engine room. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 28 February 2004
Resolution: # 1 salt water punppacking gland was renewed to satisfaction of class. As per fax dated 02 MAR 04.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Hold back found and used on water tight door starboard side, forward in engine room, leading to tunnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item resolved to statisfication of classification society, fax rcvd 27 Feb 04.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Engne entrance door/fire door was found in operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 28 February 2004
Resolution: Repairs to fire door were made to the satisfaction of class. As per fax dated 02 MAR 04.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 26 February 2004
Resolved
Junction box cover found hanging loose in CO2 room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item resolved to satisfication of class, by fax recieved 27 Feb 04
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 February 2004
Resolved
Co2 bottles for forward paint locker were mising lead wire seals, Unable to check quantity of medium in containers
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item was repaired to staisfaction of class, as per fax dated 27 Feb 04
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 26 February 2004
Resolved
Emergency fire pump unable to take suction durring testing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item was reaired to satisfication of class, as per fax dated 27 Feb04
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 February 2004
Resolved
OWS separator was found inoperable in engine room. Chief Engineer states it has been down since mid December 2003.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 27 February 2004
Resolution: Item repared to satisfaction of classification society, as per fax dated 27 Feb 2004.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 26 February 2004
Resolved
Vessel not in compliance with Safety Management Code (ISM Code). Fundamental Requirements 1.4.2
Vessel could not produce Non-conformaty reports for multiple items. In engine room, to include but not limited too; inoperable OWS, # 6 cylinder salt water leak, steam generator, emergency fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 21 February 2010
Resolution: External Audit was conducted by an recognized organization,
Lifesaving › Lifeboat
Issued 3 April 2003
Resolved
LIFEBOAT STARTING BATTERIES - IMPROPER ARRAINGEMENT (ADDITIONAL BATTERY PLACED IN SEAT). LEGACY COMPONENT DESC: Propulsion Starting System
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 3 April 2003
Resolution: RCVD LTR FROM CLASS STATING PROBLEM HAS BEEN ADDRESSED.
Fire Fighting › Miscellaneous Items
Issued 3 April 2003
Resolved
FIRE ALARM AND GENERAL ALARM SYSTEM INOPERATIVE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 April 2003
Resolved 3 April 2003
Resolution: RCVD CLASS REPORT STATING PROBLEM HAS BEEN ADDRESSED.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 April 2003
Resolved
REPLACE GLASS IN PORT BRIDGE WING DOOR.
Condition: Damaged By Earlier Event
Due 3 May 2003
Resolved 15 May 2003
Resolution: Cleared by fax.
Documentation › Certificates/Documents
Issued 30 August 2002
Resolved
The vessel needs to provide flagstate endorsement or proof of application for all licensed personnel.
Due 2 October 2002
Resolved 8 October 2002