Records from 2019 to 2025. Most recent: inspection, 15 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)26.0 ft × 10.0 ft × 3.5 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEACHCAT BOAT LLC · OLDSMAR · built 2019
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portFOLLY BEACH, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
9 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 9
15 October 2025
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8253489
31 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8020910
24 October 2023
Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7813356
20 October 2022
Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7581030
19 October 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7580686
26 October 2021
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7337722
2 September 2021
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7302482
18 December 2019
Initial Certification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6876272
25 February 2019
Hull Examination · Construction Oversight · Internal Structural Exam · Deadweight Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6820731
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 October 2025
Resolved
Whenever damage to hull plating that may affect the seaworthiness of a vessel is discovered in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service and to effect permanent repairs.
Noted damaged keel on port and starboard bow sections. Fiberglass was thin with water leaking out. Provide written repair proposal and return vessel to original structure.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 December 2025
Resolution: O/o repaired hull damage, attended vessel to evaluate fiberglass repairs.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 October 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
Observed operation of bilge high water alarm on the port side audible indication sounded, visual indication did not illuminate at the operation station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 23 January 2026
Resolution: Port side bilge alarm was replaced, witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 October 2025
Resolved
At least one ring life buoy must be fitted with a lifeline.
Observed lifeline not connected to ringbuoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 23 January 2026
Resolution: Life ring clip was replaced and connected to the ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Vessel has 3" crack in the transom near motor mount.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 24 February 2025
Resolution: Crack has been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 October 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Fuel tank level sensor wiring has deteriorated.
46 CFR 183.200 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 2 December 2024
Resolution: Vessel representative sent picture of fixed wiring
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 October 2024
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Vessel's first aid kit was incomplete and has expired medication.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 2 December 2024
Resolution: Vessel owner submitted pictures to Sector Charleston showing that expired medicine had been replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 October 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] section of transom has damage in coating causing water ingress near engine mount.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 5 January 2024
Resolution: Repairs will be made to the transom during the engine changeout winter of 2024.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2023
Resolved
Portable fire extinguishers installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Portable fire extinguisher bracket heavily corroded and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 5 January 2024
Resolution: A new bracket was placed in service.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 October 2022
Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section. (1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not have an inspection within the 3 months before or after the anniversary date of the Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2022
Resolved 3 November 2022
Resolution: Conducted satisfactory COI Renewal Inspection. Issued COI. Deficiency Rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 September 2021
Resolved
Vessel's portable bilge pump was not on the vessel and available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2021
Resolution: A portable bilge pump was placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 September 2021
Resolved
Vessel did not have a floating waterlight on the vessel. Limited to dalight only operations until a USCG approved waterlight is placed in service.
Action required: 705 - Other - as specified
Resolved 2 September 2021
Resolution: A USCG approved waterlight was placed on the vessel.