Records from 2019 to 2025. Most recent: inspection, 18 September 2025.
Inspection history · 8
18 September 2025
VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8276040
11 October 2023
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7806412
2 October 2023
COC-CHEM & TVE Renew · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7800387
7 September 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7306951
23 July 2021
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7266674
21 June 2021
PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7224568
7 August 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6772851
6 August 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6775368
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 October 2023
Resolved
THE CONDITIONS OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL ASPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP PERSONS ONBOARD.
THE VESSEL HAS NUMEROUS BROKEN OR MISSING GROUNDING STRAPS ACROSS ENTIRE CARGO DECK PIPING FLANGES.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2023
Resolution: Undersigned surveyor confirmed by company’s information that additional bonding cables were supplied and installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2023
Resolved
FIRE DOORS IN GALLEY BOUNDARIES AND STAIRWAY ENCLOSURES SHALL SATISFY THE FOLLOWING REQUIREMENTS: THE DOORS SHALL BE SELF-CLOSING. IN ADDITION HOLD BACK HOOKS ARE PROHIBITED.
SELF-CLOSING DOORS REQUIRED IN ACCORDANCE WITH THE FIRE CONTROL PLAN FAILED TO SELF-CLOSE FOUND THROUGHOUT THE HOUSE. FURTHERMORE FOUND HOLD BACK GOOKS ON DOORS IN THE GALLEY.
Action required: 10 - Deficiency Rectified
Resolved 3 October 2023
Resolution: DOOR EQUIPMENT WAS ADJUSTED SO AS TO ENSURE SELF-CLOSING. HOLD BACK HOOKS WERE REMOVED.
02 - Structural Conditions › N/A - No Subsystem › Cargo pumproom
Issued 21 June 2021
Resolved
74 SOLAS (2014 Cons.) CH 1, REG 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure tht the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The starboard side drain line to the cargo pump room bilge is wasted at the welded joint.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 23 July 2021
Resolution: CLASS REPORT SHOWING SATISFACTORY REPAIRS RECEIVED
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 21 June 2021
Resolved
46 CFR 39.2001(j): Each vapor connection flange face must have a permanent stud projecting outward that has a 12.7mm(.5 inch) diameter and is at least 25.4mm (1 inch) long. The studs as described (vapor contol line flange) is wasted and no longer meets requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 23 July 2021
Resolution: CLASS REPORT SHOWING SATISFACTORY REPAIRS RECEIVED
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 August 2019
Resolved
0940 Vessel must employ an approved Ballast Water Management System(BWMS) or use approved alternate. Vessel does not have approved BWMS and plans to discharge ballastin U.S. waters. Educated Master of requirements and cleared.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: Master educated on requirements.