M/V STEPHEN T is a 1977 towing vessel. The Coast Guard has recorded 23 inspections since 1996, most recently in July 2025, along with 10 deficiencies and 4 casualty investigations between 2010 and 2021.
Records from 1996 to 2025. Most recent: inspection, 10 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 9.5 ft
Registered tonnagegross 168 / net 115
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON INDUSTRIES · ST BERNARD, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHUNTINGTON, WV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it168 - Regulatory (Subpart C or D), Gross Ton 115 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 December 2020Resolved
Port main desiel engine experienced a electronic control module failure (ECM) and lost proupluson of port engine while underway. (STBD remained online and unaffected) Repairs pending.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2020
Resolved 24 February 2021
Resolution: Repairs complete
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Port generator battery box lid missing securing bolt.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 August 2020Resolved
Pressure vessel spring-loaded relief valves are to be set to prevent pressure from exceeding the MAWP by more than 10 percent (MAWP is established by the manufacturer). Verify setting of relief valves on air receivers and provide proof of MAWP/valve settings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2021
Resolution: New relief valves installed (125 psi)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Electric box in AFT starboard area of engine room was placed in improper service and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Panel sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 August 2020Resolved
Electrical conductors passing through watertight bulkheads must be installed so that he bulkhead remains watertight. Two openings in the forward bulkhead of the engine room were not made watertight. Seal these opening so they are watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Bulkhead sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 August 2020Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. On each of four engines, the turbos were not properly lagged. Place adequate lagging on turbos.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2021
Resolution: Cleared
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 August 2020Resolved
Alarms must be visible and audible at each operating station. The bilge alarm was not labeled on the bridge. Also, the fire alarm for "Zone 1" and "Zone 2" were not labeled on the bridge. Properly label alarm indicators at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2020
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2020Resolved
Each type I lifejacket must be marked with the name of the vessel. Found lifejackets without the vessel name indicated. Mark as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Lifejackets properly marked
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2020Resolved
Where flammable or combustible products are stored, a 40–B portable fire extinguisher must be located near the storage room or cabinet. A 40-B was not available near the storage space. Provide a 40–B portable fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Portable fire extinguisher located near the flame locker
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 August 2020Resolved
Emergency lighting must be provided for all internal crew working and living areas. Internal emergency lighting in the crew's lounge was missing or inoperable. Verify proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: Emergency lighting in crew lounge operable.
4 February 2010Routine · role: Involved in a Marine Casualty · activity 3676017
30 April 2016Routine · role: Involved in a Marine Casualty · activity 6015097
18 February 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7152074
12 May 2021Routine · role: Involved in a Marine Casualty · activity 7195465
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.