← All vessels
MEHMET DADAYLI
MEHMET DADAYLI is a freight ship. The Coast Guard has recorded 3 inspections since 2023, most recently in April 2026, along with 5 deficiencies.
Records from 2023 to 2026. Most recent: inspection, 19 April 2026.
- Built
- Not recorded
- Last inspected
- 19 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9749984 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FCC7
1583113
Flag
PANAMA
—
Maury page id
psix-1583113
Inspections, by type
Years with a record
2 calendar years (2023–2026)
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it21574 - Convention (Subpart B), Gross Ton
34484 - Dead Weight, Metric Ton
42656 - Displacement, Metric Ton
51574 - Simplified, Gross Ton
11199 - Convention (Subpart B), Net Ton
11199 - Simplified, Net Ton
34484 - Dead Weight, Metric Ton
42656 - Displacement, Metric Ton
51574 - Simplified, Gross Ton
11199 - Convention (Subpart B), Net Ton
11199 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
19 April 2026
In-Service Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8352112
1 April 2026
Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8340185
14 March 2023
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644327
Deficiency record · 5
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 1 April 2026
Resolved
For every ship to which chapter I applies, the Administration shall establish appropriate minimum safe manning following a transparent procedure, taking into account the relevant guidance adopted by the Organization. The Second Engineer departed the vessel after receiving significant burns due to recent machinery fire.
74SOLAS(24)V/14.2.1 Code 60ac
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 April 2026
Resolved
A fixed fire detection and fire alarm system shall be installed in machinery spaces where the main propulsion and associated machinery, including the main sources of electrical power, are provided with various degrees of automatic or remote control and are under continuous manned supervision from a control room. The heat/smoke detectors in the machinery space in the vicinity of the boiler, incinerator, and waste oil tank were severely damage rendering inoperable due to fire.
74SOLAS(24) II-2/7.4.1.2.2 Code 60ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 April 2026
Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed that the fire door leading to the engine room not properly functioning due to fire.
74SOLAS(24) II-2/9.1.3 Code 60ac
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 April 2026
Resolved
Fixed local application fire-extinguishing systems are to protect areas such as the following without the necessity of engine shutdown, personnel evacuation, or sealing of the spaces. The hyper-mist fixed-extinguishing systems failed to operate auatomatically when the ship suffered a machinery space fire.
74SOLAS(24) II-2/10.5.6.3 Code 60ac
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain safe to proceed to sea without danger to the ship or persons on board. During a recent machinery fire, the ship sustained damage on upper-deck emergency lighting, auxiliary boiler, and general alarm/public address systems on upper deck. The systems were rendered inoperable due to machinery space fire.
74SOLAS(24)1/11 (a) Code 60ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.