Records from 2019 to 2025. Most recent: inspection, 16 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
16 April 2025
COI Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101982
10 August 2024
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7978169
22 April 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7863551
8 April 2024
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7892494
16 May 2023
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7694414
18 April 2023
Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7670620
22 June 2022
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7484504
8 April 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7427313
20 May 2021
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7202351
16 February 2021
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7141468
14 July 2020
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7006119
19 December 2019
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949438
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2025
Resolved
Small batteries. Each small battery installation must be located in a well ventilated space and protected from falling objects. A small battery installation must not be in a closet, storeroom or similar space. Battery tops are exposed. Install battery covers to ensure protected from falling objects to the satisfaction of the attending marine inspector.
46 CFR 183.354(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 18 April 2025
Resolution: Battery covers installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which
it is installed and capable of operating at constant marine load... operator reported vibration on stbd inner engine. Cause is unknown. Determine cause and make repairs to satisfaction of attending marine inspector. Vessel to stop passenger operations upon completion of ops on 09AUG2024.
Action required: 705 - Other - as specified
Resolved 12 August 2024
Resolution: Replace engine (Suzuki 300hp)in-kind.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 April 2024
Resolved
Each first aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12.2 If the first-aid outfit contains expiry-dated items, the date of expiry shall be marked on the outside of the waterproof container, or visible through the container.
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Date of expiry marked on the outside of the waterproof container as required.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2024
Resolved
For each marine casualty required to be reported by 46 CFR 185.202, the owner , agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly in volved in the casualty. Vessel alcohol test strips expired. Vessel Captain to provide in-date alcohol test strips as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
Resolution: Alcohol test strips replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 8 April 2024
Resolved
Crack identified on port fwd freeman hatch, ivo hinges. Repair to original for credit dry dock.
Action required: 705 - Other - as specified
Resolved 15 April 2024
Resolution: Rectified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 April 2024
Resolved
Window on port side is cracked/damaged. Replace to original for credit dry dock.
Action required: 705 - Other - as specified
Resolved 15 April 2024
Resolution: Rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 April 2024
Resolved
Port side bulkhead has paper towel in cable run hole. Remove paperwork and make space vapor tight for credit dry dock.
Action required: 705 - Other - as specified
Resolved 12 April 2024
Resolution: Paper towel was removed and space was made vapor tight with expansion foam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Combustible waste receptacle being used throughout the vessel. Remove waste receptacles from the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2023
Resolution: Owner removed combustible garbage cans from the vessel - all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 18 April 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 May 2023
Resolution: Master Ms.Darminio obtained her FCC Marine Radio Operator Permit. - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 April 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible, U.S. Coast Pilot [name withheld] List and Current tables. Current tables were only provided electronically and CG Light List was missing. Provide appropriate charts & nautical publications for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 May 2023
Resolution: Owner replaced nav charts and publications with 2023 updates - all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 April 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. All closure devices must be readily available. Forward, starboard vent closure device was corroded and unable to close. Vessel rep fixed at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 18 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2022
Resolved
An enclosed space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower must be equipped with a flammable vapor detection device in compliance with § 182.480. The vapor detection device was not working as required. Repair/replace vapor detection device and prove proper operation to attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2022
Resolution: Vapor detection system checked and cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2022
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. The COI and Stability letter were not posted as required. Post the COI and Stability letter as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: Posted
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Current tables. Vessel did not have up-to-date Current table. Provide up-to-date Current tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible indicating purpose of the valve and direction of operation. The diesel F/O valves for heaters were not marked. Properly mark valves as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: Labled.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 May 2021
Resolved
Vessels EPIRB must comply with requirements for station license (NOAA registration). Vessels EPIRB is not currently registered with NOAA.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 7 June 2021
Resolution: Received email to clear deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 20 May 2021
Resolved
Child lifejackets shall be stowed separate from the adult life jackets. Found child and adult life jackets stowed together on the upper deck, bench seat located aft of the pilot house.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 7 June 2021
Resolution: Recieved email with pictures to clear CG-835
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2020
Resolved
THE THREE DIESEL TANKS FOR THE HEATERS DO NOT HAVE FLAME SCREENS ON THE VENTS. INSTALL 30X30 FLAME SCREEN ON VENTS FOR DIESEL TANKS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 20 May 2021
Resolution: Vessels crew attached 30x30 mesh screen to vents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020
Resolved
Post emergency instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 20 May 2021