Records from 2019 to 2026. Most recent: inspection, 19 February 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 3.2 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIGHTSEER MARINE PRODUCTS INC · Hudson, FL, UNITED STATES · built 2019
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
19 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8317451
12 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8251839
3 February 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8060359
14 February 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7865094
24 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853769
15 February 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7637414
10 January 2022
Annual Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7376887
25 February 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7146422
3 March 2020
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6919006
1 August 2019
Hull Examination · Deadweight Survey · Administrative Inspection · Construction Oversight · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6883654
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 February 2026
Resolved
Fire extinguisher located at the helm needs to have a bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2026
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 19 February 2026
Resolved
Asprin has expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 February 2026
Resolved
Drill log needs to be updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 January 2022
Resolved
Anchor light aft bulb not working. Make repairs and Test to satisfaction of attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2022
Resolution: Replaced bulb, tested SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 January 2022
Resolved
First aid kit had expired itmes. Must replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 14 February 2022
Resolution: New first aid kit meeting 160.041 onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 February 2021
Resolved
No Paper charts on board and Garmin GPS was not updated with latest software version. Either have onboard a CG approved paper chart or update GPS with latest software.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 7 May 2021
Resolution: Received screen shot of GPS with latest software version installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 February 2021
Resolved
Compass light now working. Vessel is restricted to day light hours only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 7 May 2021
Resolution: Received picture of light on
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2021
Resolved
Life jacket stowage was not labeled with Qty in each location. Must label each life jacket stowage with Qty.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2021
Resolved 7 May 2021
Resolution: Received picture with proper labeling
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 3 March 2020
Resolved
Vessel must have 6 red and 6 orange flares. Currently the vessel has 3 of each. Provide.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: Appropriate amount of flares were purchased and placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 March 2020
Resolved
EPIRB is located under the canopy. Relocate so that I can float free.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2020
Resolution: EPIRB has been located to a float free location.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2020
Resolved
Vessel must have FCC safety certificate
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: FCC Safety Certificate has been applied for, and is currently enroute.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 March 2020
Resolved
Captain must have FCC radio operators permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: Captain has completed all requirements for the FCC radio operators permit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 March 2020
Resolved
Provide coast pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: Coast pilot and light list were acquired and placed on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2020
Resolved
Post vessels name, official number, and hailing port.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2020
Resolution: Official numbers were mounted to a plate and riveted into place.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 March 2020
Resolved
Measure and mark loading marks per remote stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2020
Resolution: Loading line was marked with a red stripe on the port and stbd side.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 March 2020
Resolved
Mark remote fuel shut – off with direction of operation, and purpose of value in 1” letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: Remote fuel shut-off valve was properly marked, and is within OCMI standards.