MAURY USCG vessel records Sign in
← All vessels

OCEAN RADIANCE

OCEAN RADIANCE is a 2000 tank ship. The Coast Guard has recorded 10 inspections since 2008, most recently in March 2018, along with 8 deficiencies and 3 operational controls.

Records from 2008 to 2018. Most recent: inspection, 29 March 2018.

Built
2000
Last inspected
29 March 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9194969 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-15901

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2008–2018)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46021 - Convention (Subpart B), Gross Ton
13807 - Convention (Subpart B), Net Ton
68085 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

29 March 2018 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6379706
21 March 2017 Ballast Water Examination · Deficiency Check · Administrative Inspection · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6108294
21 March 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6223802
25 October 2016 NPV Safety Exam
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 6061019
15 March 2016 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5833483
25 February 2010 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3686181
4 February 2009 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3412262
21 January 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3397556
15 January 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3130568
15 January 2008 COC-GAS Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3130569

Deficiency record · 8

Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 21 March 2017 Resolved
0799-Other(Firefighting Equip)-The system should be capable of covering all areas mentioned in 11.3.1 with uniformly distributed water-spray. The Inspector found 33 nozzles partially or fully clogged. 74SOLAS(14)VII/13.1 IGC Code 9.3.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 22 March 2017
Resolution: Received proper attestation and pictures from master.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 25 February 2010 Resolved
Vessels incinerator has 3 inch gap between the door and the main body of the unit, causing warping and cracking of the metal. Vessel must submit a report from the certificate issuing authority attesting to the proper/safe operation of the incinerator. 74SOLAS Ch. 1 Reg 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2010
Resolved 1 April 2010
Resolution: received class survey report attesting to proper repair and function
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 25 February 2010 Resolved
Vessel could not demonstrate the proper operation of the port side emergency shutdown valves. Prior to departure vessel must prove proper operation of the ESD to the certificate issuing authority. IGC Ch. 5.6.4
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2010
Resolved 1 April 2010
Resolution: received class survey report attesting to proper repair and function
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 25 February 2010 Resolved
Vessel's deck water spray nozzles are clogged on the compressor and motor rooms. Vessel must provide documentation from the certificate issuing authority to the proper operation of the deck water spray system and all nozzles prior to departure. IGC Reg. 11.3
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2010
Resolved 1 April 2010
Resolution: received class survey report attesting to proper repair and function
Documentation › Certificates/Documents › IOPP Certificate
Issued 4 February 2009 Resolved
The IOPP form A does not reflect the change for new OWS content meter.
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 7 February 2009
Resolution: Received survey report attesting to changes to the IOPP. See attached document.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 15 January 2008 Resolved
Vessel's ship service general #3, cylinder #4 has a fuel oil leak on the high pressure fuel pump. Vessel shall submit documentation from the certificate issuing authority attesting to repair of the fuel leak within 30 days.
Due 15 February 2008
Resolved 15 January 2008
Resolution: Received class report attesting to repairs.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 15 January 2008 Resolved
Vessel's deck water spray nozzles are clogged on #1 and #2 cargo tank domes, both port and starboard manifolds, the compressor and motor room, and the upper portion of the superstructure. Vessel is to provide documentation from the certificate issuing authority attesting to the DWSS and all nozzles prior to conducting cargo operations and departure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2008
Resolution: Received class report attesting to proper operation of all deck water nozzles.
Lifesaving › Lifeboat › Carriage Requirement
Issued 15 January 2008 Resolved
11 lifeboat rations are no longer alltight. The vessel is to provide documentation attesting to the receipt of lifeboat rations onboard the vessel prior departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2008
Resolution: Received class report attesting to the procurement of rations for lifeboats.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.