MAURY USCG vessel records Sign in
← All vessels

ENGLISH BAY

ENGLISH BAY is a 2000 freight ship. The Coast Guard has recorded 31 inspections since 2003, most recently in January 2023, along with 11 deficiencies and 4 operational controls.

Records from 2003 to 2023. Most recent: inspection, 4 January 2023.

Built
2000
Last inspected
4 January 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9218038 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
HONG KONG
—
Maury page id
psix-15918

Inspections, by type

…with no type recorded10
Years with a record 14 calendar years (2003–2023)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19925 - Convention (Subpart B), Gross Ton
11044 - Convention (Subpart B), Net Ton
40874 - Displacement, Ton
32833 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

4 January 2023 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7616259
22 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6724211
22 June 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6726997
1 November 2018 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6564413
16 August 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6514410
9 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6334706
20 September 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6265236
11 April 2017 Administrative Inspection · COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118085
3 September 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5981969
3 May 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4844776
8 September 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4139323
12 July 2011 ISPS III Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4079358
22 September 2010 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey · ISPS II Exam · PII Safety Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3851446
29 June 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3252947
24 June 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3246338
16 June 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3239175
15 January 2008 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3126949
11 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3129419
8 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3127036
5 November 2007 Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3093137
5 November 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3093703
15 September 2006 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2774360
30 September 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2504826
10 August 2005 Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2456289
28 March 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2319902
15 February 2005 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2291051
22 December 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2263304
30 July 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2149607
13 February 2004 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006044
22 December 2003 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1966678
19 December 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1980706

Deficiency record · 11

Lifesaving › Inflatable Liferafts › Container Marking
Issued 20 September 2017 Resolved
0620- Inflatable life rafts- All life saving appliances and arrangements shall comply with the applicable requirements of the code. The container shall be marked with required information. Forward 06 man life raft was missing required information. '74SOLAS('14)III/34 & LSA Code 4.2.6.3 Action Code: 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2018
Resolution: Photos attest to new liferaft and proper markings.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 24 June 2008 Resolved
2099 - FOREWARD LIFERAFT STOWED IN BOS'N LOCKER AND NOT READY FOR IMMEDIATE USE POSING SAFETY RISK TO THE CREW 74 SOLAS III/20.2 (2004 CONS EDITION) - 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 24 June 2008
Resolution: LIFERAFT WAS MOVE TO THE APPROPRIATE LOCATION
Operations/Management › Drills/Instruction › Fire
Issued 5 November 2007 Resolved
Crew failed to demonstrate fire fighting procedures during 2 separate fire drills due to apparent failures in crew's unfamiliarity with equipment, shipboard procedures and lack of initial action taken.1. Failed to check adjacent spaces to establish fire boundaries. 2. Fire suits torn and reflective material coming off. 3. Fire suits not donned correctly. 4. Fire suits not appropriate size for crew
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2007
Resolved 7 November 2007
Resolution: Vessels crew conducted a satisfactory fire drill in the presence of USCG inspectors. Damaged fire fighters outfits has been removed from the vessel and replaced with new suits.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 5 November 2007 Resolved
SOFT PATCHES/TEMPORARY REPAIRS WERE FOUND ON SALT WATER COOLING LINES FOR REFRIGERATION SYSTEM. NO NON-CONFORMITY REPORTS HAVE BEEN SUBMITTED TO COMPANY AND NO CORRECTIVE ACTION HAS BEEN TAKEN. ADDRESS TO THE SATISFACTION OF CLASS. SOLAS 74/78 I/11, ISM CODE 9.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 December 2007
Resolved 7 November 2007
Resolution: Received class report stating temporary repairs are sufficient for now. Permanent repairs will be made completed no later then 18 DEC 07.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 5 November 2007 Resolved
SHIPS SCBA AIR COMPRESSOR IS NOT BEING MAINTAINED IAW MANUFACTURES INSTRUCTIONS. NO RECORD OF MAINTENANCE IS BEING KEPT. COMPRESSOR IS BEING USED TO REFILL AIR BOTTLES IN A MACHINERY SPACE, WHICH WILL ALLOW FOR CONTAMINATION OF THE AIR BOTTLES. COMPRESSOR OIL WAS FOUND STORED NEXT TO AIR FITTING CONNECTIONS WHICH NEED TO BE OIL FREE. EEBD'S ARE BEING OVERFILLED & NOT BEING MAINTAINED. ISM CODE 10.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2007
Resolved 7 November 2007
Resolution: Received class report that compressor is now being maintained properly. Maintenance manual and operating instructions are now being maintained. Also all EEBD bottles were serviced and corrected.
Lifesaving › Inflatable Liferafts › Servicing
Issued 5 November 2007 Resolved
CONTAINERS FOR LIFERAFTS WERE MISSING THE CONTAINER SECURING/INSPECTION SEALS. THIS COULD HAVE ALLOWED FOR WATER TO ENTER THE CONTAINERS PREVENTING THE RAFT TO DEPLOY PROPERLY. THE RAFTS ARE SCHEDULED TO BE SERVICED IN APRIL 2008. HAVE CLASS PROVIDE DOCUMENTATION THAT THE LIFE RAFTS ARE ACCEPTABLE. SOLAS 74(AM) III/20.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 December 2007
Resolved 7 November 2007
Resolution: Received class report that life raft will be inspected and serviced at dry-dock on JAN 2008
Lifesaving › Lifeboat › Safety Belt
Issued 5 November 2007 Resolved
WHILE INSPECTING STARBOARD LIFEBOAT INSPECTORS NOTICED TWO SEAT BELT BUCKLES MISSING. ITEM WAS RECOGNIZED BY 3RD OFFICER BUT NOT RECORDED IN MAINTENANCE RECORDS. LSA CODE 4.6.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 8 November 2007
Resolved 7 November 2007
Resolution: Received class report that seat belts were on-board and installed appropriately.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 5 November 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 December 2007
Resolved 15 January 2008
Resolution: Received class report from vessel via fax. Deficiency has been rectified and class report approved by Marine Inspector.
Documentation › Logs/Records › Oil Record Book
Issued 15 February 2005 Resolved
Immediately begin entering all operations required to be logged in the oil record book to the satisfaction of the Coast Guard. Several uses of the oil water separator were not logged in the oil record book. MARPOL 73/78 Annex I/20.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 March 2005
Resolution: Chief Engineer has been making proper entries into the Oil Record Book and is satisfactory.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 30 July 2004 Resolved
Vessel missing a "Junior Seaman" as required by the Minimum Safe Manning Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2004
Resolution: Received a, faxed, letter of dispensation from the flag state allowing the vessel to sail without the Junior Seaman.
Pollution Prevention/Response › Prevention Equipment
Issued 22 December 2003 Resolved
Incinerator refractory -- repair as original where there are large cracks and pieces missing. Complete to the satisfaction of class. SOLAS 74 amd I/11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2004
Resolution: Incinerator refractory was cleared to the satisfaction of class and USCG Marine inspector.

Ownership record