LE BELLOT

LE BELLOT is a 2020 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2019, most recently in September 2024, along with 17 deficiencies.

Records from 2019 to 2024. Most recent: inspection, 26 September 2024.

Built
2020
Last inspected
26 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 September 2024
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2019–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9852418
1593534
Flag
FRANCE
Maury page id
psix-1593534

Documentation record

Tonnage as PSIX records it1359 - Dead Weight, Ton
2996 - Convention (Subpart B), Net Ton
9976 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

26 September 2024 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8009866
27 August 2024 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7989521
28 September 2023 Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7799811
11 September 2023 COC-CVE Annual · PSC A
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7789643
5 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7791332
26 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7584184
23 September 2022 PSC A · COC-CVE Initial
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7562863
14 September 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7558736
20 September 2019 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6816407

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2024 Resolved
Components of a diesel engine fuel system shall be designed considering the maximum peak pressure which will be experienced in service, including any high pressure pulses which are generated and transmitted back into the fuel supply and spill lines by action of fuel injection pumps. Connections with the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. Each main diesel electric generator had excessive oil leaks in way of several explosion relief valves and was accumulating in buckets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 24 November 2024
Resolution: Four (4) New relief valves Size/ Model 98 EVO part number 1012939800-1764526 were renewed on each main diesel electric generator, no leak observed and found in satisfactory condition by class.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 August 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed multiple large cardboard boxes being stored in the AC room in zone 2, deck 8, a Category 10 space.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 September 2024
Resolution: Vessel Master provided photograph of the AC room, showing that the space had been cleared of all cardboard boxes.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 August 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed FSD A306 located deck 3 between MVZ 1 and 2 close in approximately five seconds.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 September 2024
Resolution: Vessel Master provided video documenting the proper closure of the deficient fire door.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 11 September 2023 Resolved
11131 - Crew members assigned to the starboard liferaft launching were unfamiliar with their duties and unable to deploy and inflate a liferaft safely or in a timely manner. 74 SOLAS 20 III/19.2.1 - 10c
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 September 2023 Resolved
11108 - During the demonstration of a liferaft deployment on the starboard side, the liferaft casing was damaged causing the liferaft to be taken out of service. 74 SOLAS 20 III/21.1.1.2 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 28 September 2023
Resolution: The previously damaged liferaft found replaced with a properly serviced davit launched liferaft of the same capacity.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
07199 - For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such are classified according to their fire risk as shown in categories (1) to (14). Where the contents and use of a space are such that there is a doubt as to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed large printer and paper storage in electrical locker located across from master stateroom. 74 SOLAS 20 II-2/9.2.2.3.2.2 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 28 September 2023
Resolution: There was no paper storage noted in the locker at the time of the survey. It has been verified that the locker across from the Master’s stateroom on deck 4 is designated as category (7) “accommodation space of moderate fire risk” in the RO approved
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
07199 - Stairway enclosures for accommodation and service spaces shall have direct access from the corridors and be of sufficient area to prevent congestion having in view the number of persons likely to use them in an emergency. Within the perimeter of such stairway enclosures, only public toilets, lockers of noncombustible material providing storage for no hazardous safety equipment and open information counter are permitted. PSCO observed wooden crates under the forward crew stairway, as well as other combustible material under the stairwell behind the theatre. SOLAS 20 II-2/13.3.2.3 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 28 September 2023
Resolution: The forward crew stairways and the stairwell behind the theatre were found free of obstructions or unapproved materials
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 September 2023 Resolved
11101 - Passenger ships engaged on international voyages shall carry partially or totally enclosed lifeboats on each side of such aggregate capacity as will accommodate not less than 50% of the total persons onboard. The Administration may permit the substitution of lifeboats by life rafts of equivalent total capacity provided that there shall be no less than sufficient lifeboats on each side of the ship to accommodate 37.5% of the total persons onboard. PSCO observed stowage of wooden platform in way of passenger sitting area. 74 SOLAS 20 III/21.1.1.1 - 10c
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
07199 - Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed a plastic waste receptacle with combustibles outside Engine Room Control Room. 74 SOLAS 20 II-2/4.4.2 - 10c
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2023 Resolved
07105 - Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. Fire Screen Door # A605 closed faster than 10 seconds. 74 SOLAS 20 II-2/9.4.1.1.5.2
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
Neither shall there be any doors along any designated escape route which require keys to unlock them when moving in the direction of escape. fire door A303 located in deck 08 AC station requires a key to unlock the door in the direction of escape 07120 17c 74 SOLAS 20 11-2/13.3.2.6.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 September 2022
Resolved 23 September 2022
Resolution: Removed lock
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
escape doors from public spaces that are normally latched shall be fitted with a means of quick release. such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. quick release mechanisms shall be designed and installed to the satisfaction of the administration and in particular: 3 not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when pressure is applied to the releasing device. 07120 50 c 74 SOLAS 20 11-2/13 3.2.6.2
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 17 March 2023
Resolution: Bureau Veritas completed survey.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2022 Resolved
waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. the waste receptacle in the fitness center is housed within class"C" material and is stowed behind the lining within the space 07199 16ac 74 SOLAS 20 11-2/4.2
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 29 October 2022
Resolution: Receptacle remove / disestablished location.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
in addition to the emergency lighting required by regulation 11-1/42 and 111/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photo-luminescent strip indicators placed no more than 300mm above the deck at all points of the escape route , including angles and intersections. the deck landings in the aft category 2 stairs do not have any low location lighting/ photo-luminescent strip indicators installed on the landings at all angles and/or intersections. 07120 50ac 74 SOLAS 20 11-2/13 3.2.5.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 17 March 2023
Resolution: Bureau Veritas completed survey.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
in addition to the emergency lighting required by regulation 11-1/42 and 111/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photo-luminescent strip indicators placed no more than 300mm above the deck at all points of the escape route , including angles and intersections. the markings must enable passengers to identify the routes of escape and readily identify the escape exits. on deck seven starboard side fitness center. the corridor leading from the fitness center to the main corridor has no low location lighting. 07120 50ac 74 SOLAS 20 11-2/13 3.2.5.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 17 March 2023
Resolution: Bureau Veritas completed survey.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
doors in escape routes shall, in general open in way of the direction of escape. the door leading from the fitness center to the corridor open inward. 07120 50ac 74 SOLAS 20 11-2/13 3.1.5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 17 March 2023
Resolution: Bureau Veritas completed survey.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2022 Resolved
stairway enclosures in accommodation and service spaces shall have direct access from the corridors and be of a sufficient area to prevent congestion, having in view the number of persons likely to use them in an emergent. within the perimeter of such stairway enclosure, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. on deck six starboard side aft crew stairway leading to observation lounge had two tray racks one tied to a door release and another unsecured table blocking low location lighting. 07120 10c 74 SOLAS 20 11-2/13 3.2.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 September 2022
Resolved 23 September 2022
Resolution: Crew removed stowed gear

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.