MAURY USCG vessel records
← All vessels

KALAMAZOO

KALAMAZOO is a 2011 freight ship. The Coast Guard has recorded 10 inspections since 2019, most recently in October 2025, along with 6 deficiencies.

Records from 2019 to 2025. Most recent: inspection, 17 October 2025.

Built
2011
Last inspected
17 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9611058
9V5023
1594458
Flag
SINGAPORE
Maury page id
psix-1594458

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4679 - Convention (Subpart B), Net Ton
13049 - Dead Weight, Ton
9743 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

17 October 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8254677
24 July 2025 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8191456
23 August 2024 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7980606
8 September 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787828
10 August 2023 PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7759182
4 October 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571756
8 September 2022 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7549285
22 November 2021 PSC B · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7351587
18 December 2020 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7111805
28 October 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841690

Deficiency record · 6

14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 10 August 2023 Resolved
Every Ship of 400GT and above, and every ship which is certified to carry 15 persons or more, shall carry a garbage management plan which the crew shall follow. Vessel's garbage management plan states in section 5.2.2, "Precautions shall be exercised to ensure that the food waste is not stored under any circumstances in the refrigerated rooms where consumable frozen food items are stored." PSCO discovered food waste stored in one of the vessel's refrigerated rooms.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2023
Resolution: Received class report attesting to improved capacity for storage of garbage including food waste as well as updates mentioned to garbage management plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 September 2022 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials. the following functional requirements shall be met; ignition sources shall be restricted. refractory on incinerator door was wasted and flaking off. SOLAS (04) II-2/4.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 5 October 2022
Resolution: Vessel sent satisfactory class report attesting to repairs, see Documents for details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. The electrical panel in the closet on the Nav. Bridge is fractured in the lower righthand corner making the front panel door difficult to close. 74SOLAS(20)II-1/40.1.3
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2022
Resolved 8 December 2021
Resolution: Repaired / Rectified: Electrical panel board at navigation bridge was repaired and verified in order as per photos/statement sent from ship master dated 2021-12-01. See Survey in Documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2021 Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such at to ensure the safety of the ship and persons on board. Quick closing valve in engine room leaking, valve is for lube oil service tank. 74SOLAS(20)II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2021
Resolved 8 December 2021
Resolution: Repaired / Rectified: The quickly closing vavle for lub.oil service tank has been overhauled. After overhaul, the function testing of the valve was carried out and verified. See Class Survey in Documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2019 Resolved
Auxiliary machinery spaces which do not contain machinery having a pressure lubrication system and where storage of combustibles is prohibited, such as: steering gear room. Found bunker fuel samples in the emergency steering space.
Action required: 10 - Deficiency Rectified
Resolved 28 October 2019
Resolution: Samples were moved to the forward paint locker.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 October 2019 Resolved
Ventilation ducts shall be of steel or equivalent material. Found a section of ventilation in the emergency steering space that is corroded through.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 30 October 2019
Resolution: Section of ventilation was replaced and certified by class. Survey report uploaded in documents section.