Records from 2019 to 2025. Most recent: inspection, 17 October 2025.
Inspection history · 10
17 October 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8254677
24 July 2025
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8191456
23 August 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7980606
8 September 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787828
10 August 2023
PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7759182
4 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571756
8 September 2022
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7549285
22 November 2021
PSC B · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7351587
18 December 2020
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7111805
28 October 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841690
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 10 August 2023
Resolved
Every Ship of 400GT and above, and every ship which is certified to carry 15 persons or more, shall carry a garbage management plan which the crew shall follow. Vessel's garbage management plan states in section 5.2.2, "Precautions shall be exercised to ensure that the food waste is not stored under any circumstances in the refrigerated rooms where consumable frozen food items are stored." PSCO discovered food waste stored in one of the vessel's refrigerated rooms.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2023
Resolution: Received class report attesting to improved capacity for storage of garbage including food waste as well as updates mentioned to garbage management plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 September 2022
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials. the following functional requirements shall be met; ignition sources shall be restricted. refractory on incinerator door was wasted and flaking off.
SOLAS (04) II-2/4.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 5 October 2022
Resolution: Vessel sent satisfactory class report attesting to repairs, see Documents for details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. The electrical panel in the closet on the Nav. Bridge is fractured in the lower righthand corner making the front panel door difficult to close.
74SOLAS(20)II-1/40.1.3
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2022
Resolved 8 December 2021
Resolution: Repaired / Rectified: Electrical panel board at navigation bridge was repaired and verified in order as per photos/statement sent from ship master dated 2021-12-01. See Survey in Documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2021
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such at to ensure the safety of the ship and persons on board. Quick closing valve in engine room leaking, valve is for lube oil service tank.
74SOLAS(20)II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2021
Resolved 8 December 2021
Resolution: Repaired / Rectified: The quickly closing vavle for lub.oil service tank has been overhauled. After overhaul, the function testing of the valve was carried out and verified. See Class Survey in Documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2019
Resolved
Auxiliary machinery spaces which do not contain machinery having a pressure lubrication system and where storage of combustibles is prohibited, such as: steering gear room. Found bunker fuel samples in the emergency steering space.
Action required: 10 - Deficiency Rectified
Resolved 28 October 2019
Resolution: Samples were moved to the forward paint locker.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 October 2019
Resolved
Ventilation ducts shall be of steel or equivalent material. Found a section of ventilation in the emergency steering space that is corroded through.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 30 October 2019
Resolution: Section of ventilation was replaced and certified by class. Survey report uploaded in documents section.