Records from 2019 to 2026. Most recent: inspection, 20 January 2026.
Inspection history · 16
20 January 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8271780
15 August 2025
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8217595
21 February 2025
Administrative Inspection · Drydock Exam · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8082410
7 January 2025
Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8060439
22 October 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8024815
29 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8011217
28 November 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7829987
4 October 2023
Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7803489
25 August 2023
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7782353
21 March 2023
Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7653863
16 November 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7595641
25 August 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7549446
2 February 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7381133
8 November 2021
Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7343760
21 September 2021
Deficiency Check · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7327554
12 September 2019
Initial Certification · Plan Review "T" Boat · Construction Oversight · Deadweight Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7013933
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 January 2026
Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. The diesel flexible fuel hose for outboard engine number 5 was found to be composed of two hoses connected together, instead of being one single integral hose. 46 CFR 182.720(e)(1) Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 22 January 2026
Resolution: Flexible hose was replaced with a continuous one SAE J1942.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 January 2026
Resolved
Vessels of more than 65 feet in length must have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights. All Navlights were found to have LED light-bulbs without UL1104 marking. Provide specs that certifies that bulbs meets UL1104 compliance or replace with approved ones. 46 CFR 183.420 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 26 January 2026
Resolution: Approved UL1104 Pelco bulbs installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 January 2026
Resolved
Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. Storage containers have latches installed that prevents the life jackets to float free, requiring a person that opens the latch to release them. 46 CFR 180.78(a)(1)/ Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 3 February 2026
Resolution: Latches have been removed allowing pdfs to float free.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 January 2026
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Connections on batteries should be limited to no more than 4 per terminal. 46 CFR 176.800(a)/ ABYC E-11. Multiple batteries were found to have more than 5 electrical cables connected to a same terminal, in the batteries located at the generator room and electrical room. 46 CFR 176.800(a)/ ABYC E-11. Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 3 February 2026
Resolution: Excess cables have been removed to a cable strips, and batteries has not more than 4 cables on each terminal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 February 2025
Resolved
Prove proper operation of all new installed 06 COX Brand outboard diesel engines to the satisfaction of an attenting USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2025
Resolution: Conducted a sea trial and found fully operational, engines IDLE was reset from 800RPM to 900 RPMS, no mechanical failures were found.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 January 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessels fuel tank found to have a 2-3 inch crack on STBD side. Submit repair proposal and repair to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2025
Resolution: Tank repairs complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2024
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be at a pressure not less than 414 kPa (60 psi) at the pump outlet, which must be fitted with a pressure gauge. The pressure was 20 psi. Repair and demonstrate to CG a pressure of not less than 60 psi.
46 CFR 181.300(b)
16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 December 2024
Resolution: Fire pump replaced. To ensure 50 psi at the pump, primary fire station relocated to 2nd deck to ensure full coverage.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 22 October 2024
Resolved
To be qualified to hold any commercial radio operator license, an applicant must have the ability to send correctly and receive correctly spoken messages in the English language. Vessel Captain was not able to speak English when communicating on the radio. Demonstrate to CG the ability of the vessel Captain to send and receive messages in English on the radio.
47 CFR 13.201(a)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 12 December 2024
Resolution: Master of vessel was instructed to conduct marine casualty drill over radio. Basic understanding and speaking skills observed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2024
Resolved
Rules in this subpart shall be complied with in all weathers and the shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). No dayshapes were on the vessel. Demonstrate to CG the vessel has acquired all necessary dayshapes.
33 CFR 83.20 (a)/(e)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 12 December 2024
Resolution: Day shapes present onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 October 2024
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The master of the vessel did not know how to test the EPIRB. Demonstrate to the CG that the vessel's master knows how properly test the EPIRB.
46 CFR 185.728 (a)
50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2024
Resolved 6 December 2024
Resolution: Vessel rep tested epirb.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 September 2024
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The vessel reported a steering gear failure. The vessel shall make repairs of the steering gear to the satisfaction of the cognizant OCMI.
46 CFR 182.610 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2024
Resolution: Battery charger replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2023
Resolved
46 CFR 182.720(e)(3)Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements:Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. The port set of engines fuel supply hoses were both chaffed exposing the wire. Renew hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 5 December 2023
Resolution: Both supply and return hoses were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2023
Resolved
46 CFR 182.610(a)(1) A vessel must be provided with a main steering gear that is: (1) Of adequate strength and capable of steering the vessel at all service speeds; Port and Stbd sets of engines sea star hydraulic systems had worn components allowing metal to metal contact when operating deteriorating the metal. Make repairs or replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 30 January 2024
Resolution: Received photo graphic evidence that the the port and stbd steering rams were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 November 2023
Resolved
46 CFR 182.610(g)(1) On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (i) Bulwarks; Damage to the port embarkation bulwark. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2023
Resolved 5 December 2023
Resolution: The damage was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 October 2023
Resolved
46 CFR 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
The starboard lube oil pressure gauge is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2023
Resolved 6 October 2023
Resolution: Received video of gauge operating.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 August 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel's fuel tank found to have a 2-3 inch crack. Submit repair proposal and repair to the satisfaction of attending marine inspector.
46 CFR 176.700(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2023
Resolution: vessel repaired fuel tank.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 March 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. #2 Center void found, aluminum salt pitting in the bottom plate, appoximently 12 inch up on both sides of the keel, running the entire length of the keel. Pits ranged from 1/16" to 1/8". Provide bottom plate thickness in this area to determine the repair method to use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 2 June 2023
Resolution: Received e-mail with photos showing intallation of belzona coating over pits.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2023
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Replace the following zincs found deteriorated during the underwater survey: Starboard hull, outboard side at bulkheads 19 and 23.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 2 June 2023
Resolution: Received e-mail with picture stating wasted zincs had been replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2023
Resolved
The Officer in Charge, Marine Inspection (OCMI), may approve an underwater survey instead of a drydock examination at alternating intervals. Before credit can be given for drydock, provide a copy of the report and video for the UWILD conducted on March 21, 2023.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 28 March 2023
Resolution: Report and videos received, video files to large to be uploaded. Videos located at: https://uscg.sharepoint-mil.us/:f:/s/ [name withheld]/Errfe20_24FDpaVngE0XcIAB6YCHiWPU64o2mbLaVeJ0SA?e=Ytcqa5.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2022
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: fixed detection system to determine that the system is in operating condition. Crew did not have means to test smoke detection on board and did not provide recent testing. 46 CFR 176.810 (a)(2)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 17 November 2022
Resolution: Tested to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2022
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Fuel strainers in generator space were found with slight leaking and no drip pans installed. 46 CFR 182.455 (b)(6)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2022
Resolution: Installed drip pans
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 November 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel had only one light. 46 CFR 183.430
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2022
Resolution: Added one light o/b
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 November 2022
Resolved
Charts and Publications
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables. Vessel was missing USCG Light List. 46 CFR 184.420
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2022
Resolution: Added required pubs
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2022
Resolved
Rules in this subpart (Rules 20-31) (§§ 83.20 through 83.31) shall be complied with in all weathers. (d) The Rules concerning shapes shall be complied with by day.
Vessel did not have day shapes. 33 CFR 83.20
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2022
Resolution: Added o/b
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 November 2022
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Top decks did not have maximum passenger count labeled. 46 CFR 185.602(g)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 November 2022
Resolution: added to ladder leading to upper seating area
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 2 February 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. The starboard side aft bulwark welds broke detaching the bulwark from the weather deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2022
Resolution: Verified starboard side aft bulwark was repaired and welded in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 February 2022
Resolved
A weathertight door must be provided for each opening located in a deck house. The port side aft weathertight door would not close properly, leaving a gap between the door frame and door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 February 2022
Resolution: The frame on the door was adjusted to securely close and create a weathertight seal.