MAURY USCG vessel records Sign in
← All vessels

PACIFIC CHAMP

PACIFIC CHAMP is a 2019 freight ship. The Coast Guard has recorded 8 inspections since 2021, most recently in June 2025, along with 3 deficiencies and 1 operational control.

Records from 2021 to 2025. Most recent: inspection, 5 June 2025.

Built
2019
Last inspected
5 June 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9856244 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1596096
Flag
PHILIPPINES
—
Maury page id
psix-1596096

Inspections, by type

…with no type recorded3
Years with a record 4 calendar years (2021–2025)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it35906 - Convention (Subpart B), Gross Ton
21206 - Convention (Subpart B), Net Ton
63653 - Dead Weight, Metric Ton
75276 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

5 June 2025 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8148326
18 October 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7810798
11 October 2023 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7804518
15 June 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7478639
15 June 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7478808
3 March 2021 PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144807
2 March 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7149464
23 February 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144771

Deficiency record · 3

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2023 Resolved
11117- Life Saving Appliances - At least one lifebuoy on each side of the ship shall be fitted with a buoyant lifeline. PSCO observed all lifebuoys on deck equipped with lifelines were not equipped with buoyant lifelines. 74 SOLAS (20). III/ / 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 18 October 2023
Resolution: Vessel submitted survey report attesting to corrections made.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2023 Resolved
08199- Alarms - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed repeated main switchboard (MSB) insulation alarm activation due to a faulty fuse on the bridge navigation light panel. Crew was unable to resolve, identify the root cause, and could not rectify the MSB alarm. 74 SOLAS (20)/ I/ 11/ 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2023
Resolution: Vessel submitted documentation attesting to corrections made.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2023 Resolved
07199- Fire Safety - Paint lockers shall be protected by: A water-spraying or sprinkler system, designed for 5 L/m2 min. Water-spraying systems may be connected to the fire main of the ship. PSCO observed fire sprinkler inside of 5 gal. bucket, rendering sprinkler ineffective during an emergency situation. 74 SOLAS (20)/ II-2/ 6.3.3/ 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 18 October 2023
Resolution: Vessel submitted documentation attesting to corrections made.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.