NATIONAL GEOGRAPHIC RESOLUTION is a 2021 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2020, most recently in August 2025, along with 4 deficiencies.
Records from 2020 to 2025. Most recent: inspection, 26 August 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12786 - Convention (Subpart B), Gross Ton 3836 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
26 August 2025COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8213387
13 August 2024COC-CVE Annual · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7977937
19 October 2023VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7810937
14 August 2023COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7763439
7 August 2022PSC B · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7523516
14 September 2021COC-CVE Initial
Administrative · Activities Europe · Activity 7314195
30 September 2020COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7068383
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2025Resolved
Spaces are classified according to their fire risk as shown in categories (1) and (14). Hotel stores on deck 2 contained cardboard boxes containing flammable aerosol cans.
74 SOLAS (2020) Ch. II-2/Reg. 9.2.2.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 26 August 2025
Resolution: Flammable and combustible materials were removed from hotel stores.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 August 2025Resolved
A fixed fire-extinguishing system, required by this chapter shall comply with the provisions of the Fire Safety Systems Code. Sprinklers shall be placed in an overhead position and spaced in a suitable pattern over the nominal area covered by the sprinklers. Carpenter shop on deck 8, SRTP locker on deck 2, and engineering stores on deck 4 all had storage above storage line.
74 SOLAS (2020) Ch. II-2/Reg.10.4.1.1
FSS Code 8.5.2.5.3
Action required: 10 - Deficiency Rectified
Resolved 26 August 2025
Resolution: Store items above the storage line were removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 August 2024Resolved
07105 - Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, a door designed to re-open upon contacting an object in its path shall re-open not more than 1 m from the point of contact. PSCO observed two sliding fire doors which did not re-open when contacted. The fire doors were located at Deck 5 between reception and stair tower and Deck 6 at MVZ across from safety locker forward.
74 SOLAS 20 II-2/9.4.1.1.5.11
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 13 August 2024
Resolution: Fire doors tested satisfactory. No further CG action.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2022Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The attack team fire hose was found with a small hole in the hose.
74 SOLAS (2020) II-2/14.2.1.2
10C
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 7 August 2022
Resolution: Hose was taken out of service and replaced with new hose.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.