PROGRESS 10

PROGRESS 10 is a tank ship. The Coast Guard has recorded 12 inspections since 2020, most recently in August 2022, along with 36 deficiencies.

Records from 2020 to 2022. Most recent: inspection, 24 August 2022.

Built
Not recorded
Last inspected
24 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 August 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2020–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9213208
E5U3586
1596782
Flag
COOK ISLANDS
Maury page id
psix-1596782

Documentation record

Tonnage as PSIX records it8727 - Dead Weight, Ton
2621 - Convention (Subpart B), Net Ton
5372 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

24 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7542898
5 July 2022 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7486330
29 March 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7425473
24 January 2022 COC-TVE Renew · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7382526
27 August 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7298468
5 April 2021 Administrative Inspection · PSC B · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7165172
19 March 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7144544
21 October 2020 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082068
21 October 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7083289
10 August 2020 Deficiency Check · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7029248
11 June 2020 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6974391
8 June 2020 COC-TVE Renew · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6966625

Deficiency record · 36

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 July 2022 Resolved
The volume of low sulfur fuel oils in each tank as well as the date, time, and position of the ship when any fuel oil change over operations is completed prior to the entry into an emission control area or commenced after exit from such area shall be recorded in such a log book as prescribed by the administration. Fuel change over procedures/ operations was missing the volume of fuel oils in each tank. MARPOL VI/14.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2022
Resolved 24 August 2022
Resolution: Vessel provided class report attesting to resolution.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 July 2022 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards can be ensured. Discovered exposed wires underneath the purifier electrical control panel. SOLAS 04 II-1/Reg 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 5 July 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Lagging had excessive wear on steam pipes. SOLAS 04 II-1/Reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2022
Resolved 24 August 2022
Resolution: Vessel provided class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 July 2022 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self-closing. Gasket missing from boundary door leading into the steering gear room and engine room. SOLAS01 II-2 Reg47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
Resolution: Added gasket to doors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 July 2022 Resolved
Guard rails fitted on the super structure and freeboard deck guardrails shall have at least three courses. Damage was found on the second course guard rail next to tank 3 on the starboard side. ICLL 88 Protocol/ 25.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2022
Resolved 24 August 2022
Resolution: Vessel provided class report attesting to resolution.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 July 2022 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Galley doors of class division "A" were missing gasket material. SOLAS01 II-2/Reg47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
Resolution: Added gasket material.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 January 2022 Resolved
Before the ship leaves port and at all times du ring the voyage, all life-saving appliances shall be in working order and ready for immediate use. Starboard lifeboat/rescue boat would not start and not ready for immediate use. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 January 2022
Resolution: Crew repaired lifeboat while USCG examiners were on board.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 January 2022 Resolved
Fire doors in stairway enclosures shall be self-closing and be capable of closing against an angle of inclination of up to 3.5* opposing closure. The self-closing door on the captain deck in the main stairway does not self-close. 74 SOLAS (01) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
Resolution: Self closure was adjusted by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 24 January 2022 Resolved
The machinery, boilers, and other pressure vessels piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces. Steam piping adjacent to port engine room ladder has a patch and is leaking. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
Resolution: Class determined temp repairs are sufficient and required permenant repairs should be conducted at drydock due 16DEC2022.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 January 2022 Resolved
After survey of the ship under regulation 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the Administration. Oil filtering equipment has an additional valve installed in line with the fresh water flush that is not part of the oil filter equipment design. 74 SOLAS (04) I/11.6
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
Resolution: Class inspector determined that the installed valve can be accepted and undersigned the revision on the plan.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 24 January 2022 Resolved
After survey of the ship under regulation 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey without the sanction of the Administration. L.O. sludge tank vent piping and intermediate spool piece removed from tank. 74 SOLAS (04) I/11.6
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
Resolution: Class inspector verified that the spool piece was over hauled and installed properly.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 24 January 2022 Resolved
The oil record book Part I shall be completed on each occasion on a tank-to-tank basis if appropriate, takes place in the ship: Collection and disposal of oil residues (sludge). Oil Record Book Part 1 quantity of oil residues (sludge) weekly record for L.O. sludge drain tank total quantity retained not recorded correctly. 73/78 MARPOL Cons. Ed. (2017) 3.17.2.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2022
Resolution: Oil record book entries were corrected and recorded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2022 Resolved
Electrical installations shall be that: the safety of the passenger, crew and ship from electrical hazard will be ensured. Light junction box on port downward ladder in engine room had unsecured splice wire near handrail. 74SOLAS (04) II-1/40.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 January 2022
Resolution: Crew of PROGRESS 10 re-worked the spliced wire so as not to pose a danger to the ship or crewmembers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 April 2021 Resolved
WHERE CABLES ARE INSTALLED IN HAZARDOUS AREAS, PRECAUTION AGAINST RISK TO FIRE OR EXPLOSION SHALL BE TAKEN TO THE SATIDSFACTION OF THE ADMINISTRATION. VESSEL DOES NOT HAVE INSTRISICALLY SAFE ELECTRICAL INSTALLATIONS AT STERN LOADING MANIFOLD. MUST BE CORRECTED PRIOR TO CARGO OPERATIONS.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 8 April 2021
Resolution: Received class survey showing satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 April 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. #1 AND #2 GENERATORS HAVE EXCESSIVE FUEL LEAKS.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2021
Resolved 27 August 2021
Resolution: The joint bolts at drain line were renewed. and no leaking was found during operation.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 5 April 2021 Resolved
VAPOR COLLECTION PIPING MUST BE ELECTRICALLY BONDED TO THE HULL AND MUST BE ELECTRICALLY CONTINUOUS. VAPOR COLLECTION AND RECOVERY PIPING INCLUDING P/V VALVES HAVE BROKEN BONDING STRAPS AT NUMEROUS FLANGES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 8 April 2021
Resolution: Received class survey showing satisfactory repair.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Hospital accommodation (Sickbay)
Issued 5 April 2021 Resolved
THE SECRETARY MAY ORDER ANY VESSEL TO OPERATE IN A MANNER THE SECRETARY DIRECTS IF THE SECRETARY HAS REASONABLE CAUSE TO BELIEVE SUCH VESSEL DOES NOT COMPLY WITH ANY REGUALTION UNDER ANY APPLICABLE LAW OR TREATY. SINK AND TOILET IN VESSEL HOSPITABLE SPACE ARE INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 8 April 2021
Resolution: Received class survey showing satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 April 2021 Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTANLLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS UNLESS SUCH EQUIPMENT IS OF A TYPE WHICH WILL NOT IGNITE THE MIXTURE CONCERNED. VESSEL HAS NON-INTRINSICALLY SAFE ELECTRICAL INSTALLATION IN THE PAINT LOCKER.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 8 April 2021
Resolution: Received class survey showing satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE DUPLEX STRAINER FOR THE FUEL SUPPLY IS LEAKING FUEL OIL.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 7 April 2021
Resolution: SHAFT O-RING OF FUEL CHANGE OVER SWITCH WAS RENEWED. THE DUPLEX STRAINER FOR THE FUEL SUPPLY IS NO LONGER LEAKING FUEL OIL.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2021 Resolved
DOORS REQUIRED TO BE SELF CLOSING SHALL NOT BE FITTED WITH HOLD BACKS. VESSEL HAD HOLD BACK DEVICES ON NUMEROUS SELF CLOSING DOORS
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 8 April 2021
Resolution: Received class survey showing satisfactory repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 April 2021 Resolved
VENTILATOR OPENINGS SHALL BE PROVIDED WITH WEATHERTIGHT CLOSING APPLICANCES. POWERPACK VENTILATION EXHUAST TRUNK CLOSER NOT ABLE TO BE FULLY CLOSED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 21 April 2021
Resolution: Received class report that the ventilation closer was repaired and greased on the end of hinge and butterfly nuts. After maintenance, fully open / close can be done.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 April 2021 Resolved
THE MEANS FOR SECURING WEATHERTIGHT DOORS SHALL CONSIST OF GASKETS AND CLAMPING DEVICES PERMENANATLY ATTACHED TO THE BULKHEAD OR THE DOOR. CARGO DECK PAINT LOCKER DOOR IS MISSING A DOG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 21 April 2021
Resolution: Received the class report that the dog leg onto the watertight door of cargo deck paint locker was installed and properly derusted. They then painted the door and paint locker.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 April 2021 Resolved
THE MARK OF THE AUTHORITY BY WHOM THE LOAD LINES ARE ASSIGNED MAY BE INDICATED ALONGSIDE THE LOAD LINE RING ABOVE THE HORIZONTAL LINE. "N" "K" ON LOAD LINE REPRESENTING NKK IS NO LONGER CONTRASTING TO THE HULL.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2021
Resolved 27 August 2021
Resolution: Load Line markings were painted in contrasting color.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE MAIN PROPULSION ENGINE HAD 4 CYLINDERS WITH ACTIVE JACKET WATER LEAKS WHILE STATIC.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2021
Resolved 27 August 2021
Resolution: Gaskets were renewed and no leak was found during operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE SHAFT PACKING FOR THE GENERAL SERVICE PUMP IS WASTED AND REQUIRES RENEWAL.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2021
Resolved 27 August 2021
Resolution: Gland packing was renewed and painted and not leak was found during operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2021 Resolved
WHERE "A" CLASS DVISIONS ARE PENETRATED FOR THE PASSAGE OF ELECTRIC CABLES, ARRANGEMENTS SHALL BE MADE TO ENSURE THAT THE FIRE RESISTANCE IS NOT IMPAIRED. GALLEY BULKHEAD HAS UNAPPROVED ELECTRICAL PENETRATIONS THROUGH A CLASS "A" BOUNDARY.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 5 April 2021
Resolved 27 August 2021
Resolution: Holes were closed by approved material.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2021 Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATAGORY "A" SHALL BE RESEAONABLY GASTIGHT AND SELF CLOSING. DOORS TO ENGINE ROOM AND STEERING GEAR WERE NOT SELF CLOSING.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 April 2021
Resolved 5 April 2021
Resolution: FIXED DOORS TO ENGINE ROOM AND STEERING GEAR ROOM TO BE SELF CLOSING.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 October 2020 Resolved
Each cargo tank of a tankship must be equipped with an intrincsically safe high level alarm and overfill alarm. High level and overfill alarm for cargo tanks 5, 6, and 8 and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 November 2020
Resolved 17 March 2021
Resolution: Received class report that all cargo tank alarms are working properly.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 October 2020 Resolved
Each tank shall be fitted with a liquid level gauge device of approved design to indicate the maximum level to which the tank may be filled. Vessel is prohibted from taking on fuel or cargo until liquid level gauging devices are repaired.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 November 2020
Resolved 17 March 2021
Resolution: Received class report that all cargo tank alarms are working properly.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 11 June 2020 Resolved
Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship. Stanchion on starboard side supporting chain rail failed when used as a grip for disembarking pilot.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Vessel made acceptable repairs to stachion.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 June 2020 Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allow exhaust ventilation, and closure of ventilation dampers. Funnel dampers were missing gaskets, closing mechanism for aircon room fire damper was missing, aircon room fire damper found wasted and corroded.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 June 2020 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Except as provided in regulation 14(2), such covers shall be weathertight and fitted with gaskets and clamping devices. Gasket of the engine room skylight hatch was wasted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 June 2020 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steels or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent stength to the un-pierced bulkhead and weathertight when closed. The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means and shall be permanently attached to the bulkhead or to the doors themselves, and the doors shall be so arranged that they can be operated from both sides of the bulkhead. Gaskets for stack doors were wasted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2020 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Stern light housing was cracked and not watertight.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 8 June 2020 Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machiney space, or at the bilge and ballast pump control station, stating the following: Discharge of Oil Prohibited. The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste into or upon the navigable waters of the United States, or the waters of the contiguous zone, or which may affect natural resources belonging to, appertaining to, or under the exclusive management authority of the United States, if such discharge causes a film or discoloration of the surface of the water or causes a sludge or emulsion beneath the surface of the water. Violators are subject to substantial civil penalties and/or criminal sanctions including fines and imprisonment. Placard missing.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 June 2020 Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm. High level alarms for Cargo Tanks No. 3(P) 5(P) and 8(S) were malfunctioning.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 August 2020
Resolution: Remote Survey completed by Class. USCG confirmed proper operation of High level alarms for 3(P), 5(P), 8(S).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.