The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for BUBBA B (ON 1299472), retrieved 18 September 2026. mauryrecords.com/v/psix-1597144.html
Documentation record
Registered dimensions (L × B × D)25.3 ft × 14.0 ft × 5.0 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSISCO MARINE LLC DBA MARINE INLAND FABRICATORS · PANAMA CITY, FL, UNITED STATES · built 2019
DocumentationValid · issued 31 December 2025 · expires 31 December 2026
Service, as the file records itIndustrial Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton 11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
23 October 2023Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7812940
3 October 2019Deficiency Check · Uninspected Other · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6865757
Certificate of Documentation (COD) or state registration was not present. Obtain and or present a valid COD of state registration to the attending CG MI per 46 CFR 67.7
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
Missing an official log book. Obtain, fill out, and present to the attending CG MI per 46 CFR 164.80
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 October 2019Resolved
Obtain and present towing line specifications, inspect towing lines, and log monthly checks to the attending CG MI per 46 CFR 164.74
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 October 2019Resolved
Log monthly fire and safety training in vessels log book per 46 CFR 27.209
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019Resolved
Main deck fuel oil shut off valve not marked. Properly mark the fuel oil shut off valve per 46 CFR 27.207
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019Resolved
No portable fire pump or de-water pump onboard. Fit vessel with a portable pump, with output of 60 psi or greater per 46 CFR 27.301
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019Resolved
Vessels engine room is not equipped with an approved 160-B or 100 lb. CO2 extinguisher or a fixed fire-extinguishing system as required by 46 U. S. Code of Federal Regulations part 27.303(b)(1)&(2). Managing Owner is required to equip the vessel engine room with an approved 160-B or 100 lb. CO2 extinguisher or a fixed fire-extinguishing system as required by 46 U. S. Code of Federal Regulations part 27.303(b)(1)&(2).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 23 October 2023
Resolution: Proof that a 160B was installed for the engine room was provided via e-mail. Cleared.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.