FRONT EIRA is a 2019 tank ship. The Coast Guard has recorded 5 inspections since 2020, most recently in March 2025, along with 1 deficiency and 1 operational control.
Records from 2020 to 2025. Most recent: inspection, 8 March 2025.
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for FRONT EIRA, retrieved 18 September 2026. mauryrecords.com/v/psix-1597511.html
Documentation record
Tonnage as PSIX records it106862 - Convention (Subpart B), Net Ton 299995 - Dead Weight, Metric Ton 344100 - Displacement, Metric Ton 156452 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
8 March 2025COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8083538
21 October 2022PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7572254
1 June 2021COC-TVE Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7195994
14 December 2020Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7111616
17 May 2020Deficiency Check · COC-TVE Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6948399
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 17 May 2020Resolved
For tankers of 20,000 tonnes deadweight and upwards, the protection of cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. Audible and visual alarms shall be provided to indicate low water pressure or low water flow rate to the cooling and scrubbing arrangement. The low water sensor is not working rendering the audible and visual alarm inoperable. SOLAS (14) II-2/4.5.5, FSS CODE 15/2.3.2.2.3
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2020
Resolved 8 June 2020
Resolution: Vessel master provided documentation of satisfactory repairs made.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.