This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it3415 - Convention (Subpart B), Gross Ton 5001 - Dead Weight, Metric Ton 6950 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
16 December 2019ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6874381
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 December 2019Resolved
Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum working pressure and tested annually or part of bi-annual or midperiod inspections. Vessel's bunker transfer manifold was tested with air and no records were available to show last hydrostatic test. Vessel must show proof of satisfactory hydrostatic test to 1.5 times the max allowable working pressure prior to bunkering in US waters.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2019
Resolution: Received test report from last drydock in 2018 attesting to the satisfactory hydrostatic test of bunker piping.