Records from 2015 to 2026. Most recent: inspection, 5 February 2026.
Inspection history · 26
5 February 2026
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8306597
12 November 2025
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8265810
17 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8094089
30 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7923085
9 May 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909654
8 November 2023
Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7820824
7 March 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7646154
7 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7426674
9 March 2022
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7409555
23 February 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7401050
23 November 2021
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7356435
28 July 2021
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7271038
6 May 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7191968
2 May 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7190358
2 February 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7131594
21 January 2020
Plan Review "T" Boat · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6893338
29 October 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6848944
13 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6642131
8 March 2019
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6639737
28 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6459034
22 June 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6452815
4 April 2018
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6385800
17 November 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6319838
21 October 2017
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 6292618
7 February 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6084331
24 February 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5821139
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 February 2026
Resolved
All fiber reinforced plastic (FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type, installed in accordance with § 76.27 in subchapter H of this chapter. Vessel was not equipped with smoke detectors.
46 CFR 177.41(c)(3)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 18 February 2026
Resolution: Installed smoke detectors to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 February 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: minimize accidental personnel contact with energized parts. MI discovered dead end wires in the engine room.
46 CFR 183.200(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 18 February 2026
Resolution: Operator terminated wires to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 February 2026
Resolved
The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retro-reflective materials of a sufficient width (approximately 5 cm) should be applied around or on both sides of the body of the lifebuoy at four evenly-spaced points. Ring buoy on board only had two strips of retro-reflective tape.
46 CFR 185.604(i)
IMO Resolution A. 658(16
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 5 March 2026
Resolution: Operator provided photo of correct SOLAS retro-reflective tape on the life ring.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2026
Resolved
A vessel not required to have a power driven fire pump... must have at least three 2 1/2 gallon buckets, with an attached lanyard...words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Fire buckets present but in deteriorating condition.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 18 February 2026
Resolution: MI observed new fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 February 2026
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. One paddle did not have the vessel name on it.
46 CFR 185.604(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 18 February 2026
Resolution: Both paddles are properly labeled.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 February 2026
Resolved
Fire extinguishing equipment installed on a vessel...must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Testing/maintenance records for installed system not on-board.
46 CFR 181.120(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 10 February 2026
Resolution: Operator emailed report to [name withheld] to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 February 2026
Resolved
The manufacturer's instructions for onboard maintenance of survival craft, rescue boats, and launching appliances...The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Maintenance log for lifesaving, firefighting, and rigging was not kept up to date. Master has been advised to maintain these logs moving forward.
46 CFR 185.702(a)(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 February 2026
Resolved 10 February 2026
Resolution: Operator has been notified to begin tracking maintenance and to make these logs available to the MI during inspections.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2025
Resolved
General purpose resins...All fiber reinforced plastic (FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection
system in accommodation space. Vessel was found with two detectors needing new batteries.
46 CFR 177.410(c)(3)(ii)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2025
Resolution: Batteries were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to.. minimize accidental personnel contact with energized parts. Identified two dead end wires without caps/tape to prevent from accidental electrical shock.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 25 March 2025
Resolution: Dead end wires were capped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2025
Resolved
Waste receptacles... Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Trash cans on board vessel are plastic.
46 CFR 177.405(f)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 25 March 2025
Resolution: Trashcans replaced with metal ones.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 17 March 2025
Resolved
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph
4.12. First aid kit had expired medications.
46 CFR 199.175 (b)(10)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: First aid kit medications were replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 March 2025
Resolved
When an operator is on duty and respoinsible for transmitting systems...FCC license must be posted or in personal possession. FCC license not present.
47 CFR 13.19 (c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 10 April 2025
Resolution: Operator provided proof of FCC license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 March 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests including condition of the sail arrangements. Sail Rigging inventory documentation not present.
46 CFR 176. 802 (a)(3)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2025
Resolved 18 April 2025
Resolution: Operator sent Sail Rigging Inventory via email,uploaded to document tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2024
Resolved
Each ring life buoy must be marked with TYPE II retroreflective material approved in accordance with 46 CFR 64.018 or other standard specified by the Commandant. Life ring buoy did not have retroreflective tape present.
46 CFR 185.604(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Operated installed new USCG approved retroreflective tape.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel was due for inspection no later than 02 May. The vessel is unable to carry passengers until successful completion of an annual inspection, currently scheduled on 30 MAY 2024.
46 CFR 176.500 (b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Completed Annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 February 2022
Resolved
A vessel must be provided with bilge pumps in accordance with 46CFR182.520(a). Vessel's portable hand pump was inoperable during testing of bilge pumps.
46 CFR 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
Resolution: Visually inspected successful operation of hand operated bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 February 2022
Resolved
Each lifefloat must be certified to meet 46 CFR 160.073 in subchapter Q of this chapter. The lifefloat needs to be painted in an orange color.
46 CFR 180.137
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 7 April 2022
Resolution: Vessel has replaced the old lifefloat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 February 2022
Resolved
Repairs or alterations that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The vessel updated their rigging and needs to send updated preventative maintenance plan to MIs.
46 CFR 176.700
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 28 February 2022
Resolution: Received updated preventative maintenance plan.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 November 2021
Resolved
Proposed alterations shall be approved by the Officer in Charge, Marine Inspection, before work is started. Drawings, sketches or written specifications describing the alterations in detail may be required by the Officer in Charge, Marine Inspection. Vessel removed mizzen mast and boom and sail as well as a wench/capstan on the bow against the direction of the vessels stability letter (see operating restriction #7).
46 CFR 176.20-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 January 2022
Resolution: Vessel has re-installed mizzen mast boom and sail and properly repaired the deck.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 November 2021
Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. Vessels annual servicing for fire suppression systems and extinguishers were out of date.
46 CFR 176.25-25
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2021
Resolution: Vessel provided documentation of servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 November 2021
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be seperated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate or equivalent construction. Vessel had existing cable run through engine room bulkhead that needed vapor seal.
46 CFR 182.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 6 January 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. 02 stanchions on the starboard side had hairline fractures on the mount to the deck.
46 CFR 177.900(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2021
Resolved 9 December 2021
Resolution: Vessel properly repaired bases of stanchions on starboard side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2021
Resolved
The cognizant OCMI may require that a vessel and its equipment under-go any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. Rig requires third-party rigging survey.
46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2021
Resolved 7 January 2022
Resolution: Conducted third-party rigging survey
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 February 2021
Resolved
Each rescue boat must be marked with type II retroreflective material approved in accordance with 164.088. MI observed deteration of reflective tape. Operator must fix retroreflective tape prior to passnegers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2021
Resolved 11 February 2021
Resolution: Life Float now has required retro-tape IAW regulations.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2020
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has gone beyond extended drydock date. Complete drydock inspection prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2020
Resolution: Completed dry dock.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 March 2019
Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level. Current bilge high level alarm was taken out and is in the process of being replaced. Properly install in accordance with regulations.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 March 2019
Resolved 13 March 2019
Resolution: Installed new high level alarm. Video received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct an operational test of the means provided for pumping bilges. Upon arrival for inspection, the bilges were not properly cleaned and ready to conduct an operational test of the bilge pump. Make bilge pump and lines ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 4 April 2019
Resolution: Witnessed operational test of electric bilge pump to the satisfaction of attending MI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 March 2019
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency instructions posted but vessel missing required placard. Install placard with specific vessel information.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 25 March 2019
Resolution: Provided photograph of emergency radio placard.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 March 2019
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Current COD is expired, however paperwork for a new COD was submitted. Place current COD on vessel once received.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 26 March 2019
Resolution: Operator provided scanned image of current COD.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 March 2019
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. Gasket on mizzen boom is heavily worn. Investigate damage and replace as necessary.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 10 April 2019
Resolution: Vessel removed Mizzen Boom from the vessel. Will replace gasket and provide proof upon installation.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 March 2019
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The cognizant OCMI may require the owner to submit detailed calculations on the strength of the standing rigging to the MSC for evaluation. Determine the tensile strength of the single side band material vs. the standing rigging wire. Contact the marine inspector to discuss after.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 10 April 2019
Resolution: Operator removed the single side band insulators, and renewed the back stays.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2019
Resolved
At each initial and subsequent inspection for certification, the owner shall be prepared to have the vessel ready for inspection. A log of the inspections and maintenance shall be maintained by the Captains and Crew of the vessel and shall be kept on board for review as requested by USCG Marine Safety Inspectors. Maintenance records not available for review. Provide maintenance records following preventative maintenance schedule.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 17 April 2019
Resolution: Recieved up-to-date sail rig maintenance log.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 July 2018
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. Vessel needs to obtain renewed Safety Radiotelephony Certificate. 47 CFR 80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 1 August 2018
Resolution: Copy of new FCC certificate provided.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 3 July 2018
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Wires by the chart table are supported only will plastic wire ties; add metal supports at 24" interval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 27 August 2018
Resolution: Photo documentation received; metal wire supports have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 3 July 2018
Resolved
All cable and wiring must be: Be protected by metal coverings or other suitable means if in areas subject to mechanical abuse. Owner needs to install protective covering for grounding bracket under chart table.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 5 September 2018
Resolution: Received photo documentation, satisfactory rubber protective covering has been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 July 2018
Resolved
At each initial and subsequent inspection for certification, the owner shall be prepared to have the vessel ready for inspection including: Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. The cleat for the mizzen boom shackle has mechanical gouging; replace the component IAW NVIC 02-16.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 5 September 2018
Resolution: Received photo documentation, new cleat has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 July 2018
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The engine compartment has a wire run which is not vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 24 September 2018
Resolution: Received photo documentation, wire run has been filled to be vapor tight.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 July 2018
Resolved
A vessel must have one or more ring life buoys. Owner needs to replace the ring life buoy due to fading color and deterioration of material.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 1 August 2018
Resolution: Photo documetnation provided for new life ring.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 July 2018
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Operator uses a maritime consortium to manage their random chemical testing program, but does not have current proof of current enrollment.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 27 August 2018
Resolution: Operator provided prof of enrollment dated 27Dec17 to expire 31Dec18.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 17 November 2017
Resolved
Submit a draft Preventative Maintenance Plan as per NVIC 2-16.
Action required: 705 - Other - as specified
Due 17 December 2017
Resolved 14 March 2019
Resolution: VSL REP provided a copy of PMP. **Unsure of exact date of when the deficiency was rectified.
Engineering › Bilge Water Management System › Not Operational
Issued 7 February 2017
Resolved
Prove proper operation of fixed hand operated bilge pump. 46 CFR "Old T" 182.25-10
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 25 February 2017
Resolution: Bilge pump repaired.
Engineering › Bilge Water Management System › Valve
Issued 7 February 2017
Resolved
Install valve at electric submersible pump overboard. 46 CFR 182.520(e)(7)
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Shutoff valve was installed.