IBERVILLE is a 2019 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2019, most recently in June 2026, along with 6 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 15 June 2026.

Built
2019
Last inspected
15 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL4575
1598664
Flag
UNITED STATES
Maury page id
psix-1598664

Documentation record

Registered dimensions (L × B × D)40.0 ft × 14.0 ft × 5.5 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAZORHEAD ALUMINUM BOATS LLC · NEW IBERIA, LA, UNITED STATES · built 2019
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

15 June 2026 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8405128
6 August 2025 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8186637
18 June 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7924194
7 November 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7819792
25 August 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7524145
27 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7246667
11 August 2020 Initial Certification · COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7030449
27 April 2020 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6948775
16 October 2019 Construction Oversight · Inclining Experiment · In-Service Inspection · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6858362

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 July 2021 Resolved
Inspectors found engine room hatches and ventilation flaps not having gaskets to maintain vapor tightness in the engine room, a space with an installed custom fixed CO2 extinguishing system. Install hasp/cosing device as well as a gasket material to ensure vapor tightness of the space in all natural ventilation air ducts and ensure vapor tightness to engine room to the satisfaction of the attending CG inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 August 2021
Resolution: VESSEL PROVIDED PICTURES OF GASKETS MAKING THE ER GAS TIGHT
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 July 2021 Resolved
The owner or the designated representative may be required to perform functional and/or diagnostic test(s) to be witnessed by the attending CG marine inspector. Testing may be performed by the owner or the manufacturer's representative or a third party qualified technician. When discussing main engine capabilities and alarms, it was noted that the Cummins engines do reduce RPM wwhen a gauge drops below certain thresholds. Prove proper operation of the alarms IAW manufacturer's guidance or provide 3rd party technicians report attesting to proper operation to the satisfaction of the attending CG marine inspector. CG-CVC Policy Letter 17-08
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 26 August 2021
Resolution: vessel provided documentation from manufacturer that engine derate or shutdown are not active for their vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 July 2021 Resolved
A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Current data plate shows 40 degree celcius. Provide proof of de-rating, new data plate or replace generator to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 13 August 2021
Resolution: vessel provided proof of derating generator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2021 Resolved
Connections must be made with permanent type of connectors. Marine inspector found wing nuts on the battery terminals. Install lock washers under wing nuts or replace with lock nuts to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 26 August 2021
Resolution: REPLACED WING NUTS WITH NYLOCK NUTS
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 July 2021 Resolved
Vessel is currently outfitted with plastic fire buckets. Replace to the satisfaction of the atending CG marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 26 August 2021
Resolution: VESSEL PROVIDED PROOF OF METAL FIRE BUCKETS
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2021 Resolved
Vessel's FCC radiotelephony certificate was expired. Original expiration was only a year from issue date. Technician sent a new one while CG MI was onboard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 28 July 2021
Resolution: Provided updated certificate

Ownership record