← All vessels
DAS
DAS is a tank ship. The Coast Guard has recorded 6 inspections since 2020, most recently in February 2026, along with 2 deficiencies.
Records from 2020 to 2026. Most recent: inspection, 17 February 2026.
- Built
- Not recorded
- Last inspected
- 17 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9854507 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5YX8
1599003
Flag
LIBERIA
—
Maury page id
psix-1599003
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it299750 - Dead Weight, Metric Ton
344100 - Displacement, Metric Ton
156237 - Convention (Subpart B), Gross Ton
106850 - Convention (Subpart B), Net Ton
344100 - Displacement, Metric Ton
156237 - Convention (Subpart B), Gross Ton
106850 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
17 February 2026
PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8304010
18 December 2024
COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8039586
11 February 2024
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7863965
30 March 2023
COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7659763
16 September 2020
COC-TVE Renew · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7054286
11 September 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7056159
Deficiency record · 2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 18 December 2024
Resolved
The gas detection equipment shall be so designed that it may readily be tested and calibrated. PSCO observed vessel was unable to conduct flow fault alarm. 74 SOLAS (20)II-2/4.5.7.3.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 18 December 2024
Resolved
Oil tankers of 150 Gross Tonnage and above shall be equipped with an oil discharge monitoring and control system approved by the administration.. this system shall be fitted with a recording device to provide a continuous record of the discharge... This record shall be identifiable as to time and date and shall be kept for at least three years. Vessel was unable to produce record from 28Jun2024 to 18Dec2024.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.