MAURY USCG vessel records
← All vessels

KAREY-MAE

KAREY-MAE is a 2019 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2019, most recently in May 2026, along with 28 deficiencies and 1 operational control.

Records from 2019 to 2026. Most recent: inspection, 1 May 2026.

Built
2019
Last inspected
1 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1599159
Flag
UNITED STATES
Maury page id
psix-1599159

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

1 May 2026 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8359144
21 April 2026 Annual Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8329349
10 May 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8132446
5 February 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8059254
7 June 2024 Type not recorded
No type recorded · Station Charleston · USCG Southeast District (CGD-SE) · Activity 7931321
22 April 2024 Drydock Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7898060
22 March 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7883662
16 February 2023 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7637800
6 January 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7617537
13 October 2021 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7332032
19 October 2019 Construction Oversight · Drydock Exam · COI Inspection · Simplified Stability Test · Deficiency Check · DAPI Audit · Plan Review "T" Boat
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6850164

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2026 Resolved
Independent gasoline fuel tanks must be built in accordance with ABYC H-24 (incorporated by reference, see 46 CFR 175.600), or 33 CFR 183, subpart J. Port side fuel tank found deteriorating on the top-side corners. 46 CFR 182.440(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 24 April 2026
Resolution: Picture well received. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2026 Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter. The floating waterlight was found with unapproved batteries. 46 CFR 180.70(d)(1)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 24 April 2026
Resolution: Picture well received. ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 April 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date [publications.] Vessel was found with missing and out-of-date publications. 46 CFR 184.420(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 24 April 2026
Resolution: Picture well received. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2025 Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight label specifies that batteries must be "Energizer AA L91 Batteries". Vessel had the incorrect batteries for the waterlight.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Vessel owner bought new batteries of the correct type.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 February 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had dead end wiring under the center console.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Vessel owner capped off wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Waterlight was connected to lifeline and not its own lanyard.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
Resolution: Owner attached lanyard to waterlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 February 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation Direction of operation was incorrectly marked.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 March 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed Drydock and Internal Structural Examination due 31OCT23. 46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2024
Resolution: Satisfactory DryDock completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 March 2024 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection due 14JAN24. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2021 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter). Fire extinguishers received no annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2021
Resolution: Master installed new 10 and 40 B:C fire extinguishers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 October 2021 Resolved
Unless otherwise provided by this subpart, each vessel required to have a Certificate of Inspection is subject to the annual vessel inspection fee listed in table 2.10-101 for its vessel category. Vessel failed to pay user fee.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2021
Resolution: Received confirmation that user fees had been paid.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2021 Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights. All around LED light extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2021 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have a pressure type connector on each conductor; Wire nuts were used in place of pressure type connectors. 46 CFR 183.340(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2021 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drills related to emergency procedures shall be conducted quarterly. No abandon ship or man overboard drills recorded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2021 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. rills related to emergency procedures shall be conducted quarterly. No firefighting drills recorded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 October 2021 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel had three 5 gallon buckets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 19 October 2021 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Portable watertight container not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 26 October 2021
Resolution: Watertight container properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel's life jackets not labeled with vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 26 October 2021
Resolution: Life jackets labeled with vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:Be of at least 18.3 meters (60 feet) in length Vessel's lifeline only reached 50 feet in length.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 26 October 2021
Resolution: 60 ft life line installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 October 2021 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight was missing pieces, sacrificing the integrity of its intended operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 October 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel missing all charts and publications.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 12 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2021 Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25. Vessel's starboard independent fuel tank exhibited severe degradation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 November 2019 Resolved
Tide tables, and a Coast Guard Light List must be onboard in accordance with 46 CFR §184.420. The vessel was missing a Light List and Tide Tables. Prior to the carriage of passengers must have all required nautical publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 9 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 November 2019 Resolved
Vessel is required to have an illuminated magnetic compass per 46 CFR 184.402. Vessel currently does not have one.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 9 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 25 November 2019 Resolved
Vessel must be equipped with at least two operable portable battery lights in accordance with 46 CFR 183.430. Vessel does not have any portable battery lights on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 9 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2019 Resolved
Vessel is required one portable hand pump capable of pumping 10 gallons per minute in accordance with 46 CFR 182.520(a). Vessel currently only has one fixed power pump.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 9 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2019 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets with an attached lanyard placed so as to be easily available during an emergency. Vessel did not fire buckets onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 9 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 November 2019 Resolved
The employer must have a policy regarding drug and alcohol use in the workplace. Vessel does not currently have a drug and alcohol program in place.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2019
Resolved 7 January 2020

Ownership record