ENCHANTED PRINCESS is a 2020 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2019, most recently in February 2026, along with 12 deficiencies and 2 operational controls.
Records from 2019 to 2026. Most recent: inspection, 25 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it122695 - Convention (Subpart B), Net Ton 145281 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 February 2026Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway encloseures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed Fire Door 06.2.24 was unable to fully latch closed.
74SOLAS20 II-2/9.4.1.1.5.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 February 2026
Resolution: Crew adjusted the door allowing it to latch closed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 February 2025Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. PSCO's observed double-leaf door 06.2.09 in stairway enclosure not close in sequence, preventing the door from closing completely.
74 SOLAS 20 II-2/9.4.1.1.5.12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2025
Resolved 28 February 2025
Resolution: Resolved, Coast guard Member witnessed door fixed prior to leaving.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 February 2025Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow... .3 not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when the pressure is applied to the releasing device. PSCO's observed two locations where the doors along a passenger escape paths were capable of being locked by either locking latches and/or turn locks. Location 1) entrance/exit to Vista Lounge both port and starboard side. Location 2) Entrance/exit by the shops near FSD 7.3.05 and FSD 7.3.08. 74 SOLAS 20 II-2/13.3.2.6.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2025
Resolved 7 March 2025
Resolution: Vessel Flag submitted evidence that the locks have been removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 February 2025Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces, at least one of which shall give access to the stairway forming a vertical escape. PSCO observed a cat 4/7 space, directly behind the Vista Lounge in which each escape route could be locked from outside the space rendering both means of escape ineffective.
74 SOLAS 20 II-2/13.3.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2025
Resolved 7 March 2025
Resolution: Vessel Flag submitted evidence that the locks have been removed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 5 March 2024Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Boat commanders for lifeboat #5 and #10 were not familiar with the operation of the lifeboat and were not familiar with the emergency steering operations. 74 SOLAS 20 III/19.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2024
Resolution: Crewmembers received training prior to PSCOs departing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2024Resolved
Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. Escape route from the crew mess on deck 5 Stbd side was obstructed by chairs. 74 SOLAS (20) II-2/5.3.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2024
Resolution: Obstructions were removed prior to PSCO's departing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2024Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Lawn chairs in crew staircase deck 17 aft was blocking primary means of escape and stairwell.
74 SOLAS (20) II-2/13.1.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2024
Resolution: Lawn chairs were removed prior to PSCO's departing.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 29 February 2024Resolved
Notification of Breach of Security. An owner or operator required to have security plan under parts 104, 105, or 106 of this sub chapter shall, without delay, report breaches of security to the National Response Center via one of the means listed in paragraph (a) of this section.
Passenger Vessel Enchanted Princess found a breach of security on board and did not report to the National Response center without delay. Vessel delayed communication by three hours while they conducted further investigation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 9 April 2024
Resolution: Received flag attestation to completing an ISPS audit.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2022Resolved
Multiple B15 doors throughout the vessel had defects in frame due to impact damage of crew servicing cart and would not fully close. See form B attached for specific locations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 8 October 2022
Resolution: Vessel statement attesting to adequate rectification of the above related to the B-15 doors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2022Resolved
Class "A" Fire door to accomodation deck 6 wouldn't fully latch when closed. See form B for specific location on the ship.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 September 2022
Resolved 16 September 2022
Resolution: Crew was able to adjust the door to full operation prior to USCG departure fromt he vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2022Resolved
Kids play area on deck 17, port side, aft section of the vessel has pad locks on escape doors instead of quick means of escape. See form B for details.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 8 October 2022
Resolution: Vessel has provided sufficient evidence of adequate correction for the noted deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2022Resolved
INOP emergency generator
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO PATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ONBOARD.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2022
Resolved 17 September 2022
Resolution: deficiency rectifed in port. lead inspector verified