Records from 2019 to 2026. Most recent: inspection, 19 March 2026.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 4.8 ft
Registered tonnagegross 15 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2019
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portLAJAS, PR
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
19 March 2026
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8328944
22 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8286456
12 February 2025
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8082412
13 January 2025
COI Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8067340
20 June 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7942836
17 June 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7937686
26 December 2023
Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7842423
7 March 2023
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7644920
26 January 2022
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7385350
11 January 2021
Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7123842
29 January 2020
COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6897075
2 October 2019
Plan Review "T" Boat · Internal Structural Exam · Deadweight Survey · Hull Examination · Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6859808
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Upon inspection of the #1 port Void, attending MI noticed water seeping from the bottom of backing plate for ladder located on glass bottom space. Un install ladder for inspection. 46CFR176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2025
Resolved 12 February 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Seal cracks on Port side deck bellow loading ramp. 46CFR176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 12 February 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 June 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window, vessel cannot operate until annual inspection is completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2024
Resolution: Attended vessel and performed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2024
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Replace waste receptacles onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 25 June 2024
Resolution: Steel recepticles with lids.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications in accordance with CFR. Provide navigation publications as required
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 8 July 2024
Resolution: Operator provided updated light list.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 June 2024
Resolved
Each vessel inspected and certificated under the provisions of Subchapter T must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the
terms of the certificate. The vessel departed Fondo de Cristal docks in La Parguera, PR without being in full compliance with the terms of the Certificate of Inspection due to the vessel’s operations as a small passenger vessel beyond the required annual inspection’s 90-day window date of 29 April, 2024.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
Resolution: Annual inspection completed and LOW issued
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. STB fuel tank emergency fuel shut off needs to be replaced.
46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022
Resolved
life buoy must be marked in clearly legible block capital letters with the vessel's name. Life ring buoy was not marked
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2022
Resolved
Repair damaged portions of fiberglass on Port and STB bow. Summit repair proposal
Action required: 705 - Other - as specified
Resolved 27 January 2022
Resolution: Attending MI received pictures detailing the repair of this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2022
Resolved
Check and tighten all glass retaining bolts
Action required: 705 - Other - as specified
Resolved 1 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2022
Resolved
Rotted wood found in base of STBD side main deck rail #5 and 8. Submit a repair proposal.
Action required: 705 - Other - as specified
Resolved 1 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2022
Resolved
All Port side overboard bilge valves handles too long to allow valve to close. Submit repair proposal
Action required: 705 - Other - as specified
Resolved 1 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2022
Resolved
Latch for STBD side ladder broken, replace in kind
Action required: 705 - Other - as specified
Resolved 1 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents
and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked ‘‘First-Aid Kit’’. A first-aid kit must be easily visible and readily available to the crew. First aid kit missing items required by 160.041
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2020
Resolved 11 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2020
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached
to the lanyard with a corrosion resistant clip. Waterlight is missing corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 January 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
Charts of large enough scale to make safe navigation possible. Vessel doesn't have a chart.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 January 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 January 2020
Resolved
Copy of chemical testing program )company) not available to crew or USCG
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 January 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 January 2020
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members. EAP program or materials were not available to crew. Also, proof of testing for crewmembers and supervising personnel were not available.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 January 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 January 2020
Resolved
Provide Coast Guard Marine Inspector proof that alcohol screening devices (electronic) are approved by US DOT.
ASDs listed on ODAPC's Web page for “Approved Screening Devices to Measure Alcohol in Bodily Fluids” and EBTs listed on ODAPC's Web page for “Approved Evidential Breath Measurement Devices” are the only devices you are allowed to use to conduct alcohol screening tests under this part.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 January 2021