MAURY USCG vessel records
← All vessels

LADY ROSE

LADY ROSE is a freight ship. The Coast Guard has recorded 6 inspections since 2023, most recently in February 2025, along with 11 deficiencies — 3 with no resolution recorded —.

Records from 2023 to 2025. Most recent: inspection, 9 February 2025.

Built
Not recorded
Last inspected
9 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 February 2025
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2023–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9355032
1599880
Flag
PANAMA
Maury page id
psix-1599880

Documentation record

Tonnage as PSIX records it5562 - Convention (Subpart B), Net Ton
9576 - Convention (Subpart B), Gross Ton
10630 - Dead Weight, Metric Ton
16861 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

9 February 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8076865
27 September 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8010544
25 September 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8009149
21 August 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8005025
19 August 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7980691
19 December 2023 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7836055

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2025 No resolution recorded
The following functional requirements shall be met: thermal insulation of boundaries shall have due regard to the risk of the space and adjacent spaces. PSCO observed a temporary repair of insulation hanging from the ceiling of the CO2 room. 74SOLAS(20)II-2/9.1.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2025 No resolution recorded
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Cooling water piping line for generators had temporary patch. 74SOLAS(04)II-1/26.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2025 No resolution recorded
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed Cooling water pump for cargo refrigeration system leaking. 74 SOLAS (04)II-1/26.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 February 2025 Resolved
The purpose of this regulation is to control the spread of smoke in order to minimize the hazards from smoke. PSCO observed flexible hose was portably rigged from F/W supply pipe to vacuum pump for priming. Hose penetrated class A fire boundary. Crew removed and stored hose restoring fire boundary. 74SOLAS(20)II-2/8.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 February 2025
Resolved 9 February 2025
Resolution: While on board PSCO had crew remove hose and restore Class A boundary.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 9 February 2025 Resolved
Ships 500 gt and upwards shall be provided with at least one international shore connection complying with the FSS code, the connection shall be kept on board the ship together with a gasket. PSCO observed gasket for the ISC broken. Crew replaced with new gasket. 74SOLAS(20)10.2.1.7.1 FSS CODE 2.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2025
Resolved 9 February 2025
Resolution: PSCO observed crew replacing ISC gasket.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 19 August 2024 Resolved
SATISFACTORY MEANS SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN GETTING TO AND FROM THE CREW’S QUARTERS, THE MACHINERY SPACE, AND ALL OTHER PARTS USED IN THE NECESSARY WORK OF THE SHIP. PSCO OBSERVED MULTIPLE MISSING RAILINGS AROUND CARGO HOLDS, BENT RAILINGS ON DECK, AND DAMAGED/ UNUSABLE STAIRS DESCENDING A GANGWAY NEAR CARGO HOLD #ONE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2024
Resolved 21 August 2024
Resolution: Damaged/corroded railings and stairs were repaired. Pictures and class report provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT BANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED ANCHOR WASH PIPE ACTIVELY LEAKING AND WATER COLLECTING IN BOSUN STORE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2024
Resolved 21 August 2024
Resolution: Pipe and flange were replaced.See documents for more information.
01 - Certificates & Documentation › 013 - Documents › Ship Energy Efficiency Management plan
Issued 19 August 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2024
Resolved 27 September 2024
Resolution: Class and Flag provided sufficient reasoning that vessel is NOT APPLICABLE to the written regulation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 August 2024 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER. STRUCTURAL FIRE PROTECTION INCLUDING FIRE-RESISTING DIVISIONS AND PROTECTION OF OPENINGS IN THESE DIVISIONS. PSCO OBSERVED SELF CLOSING FIRE DOORS ON [name withheld] DECK STAIRWELLS UNABLE TO LATCH. 74SOLAS(04) II-2/14.2.1.1.1.1
Action required: 10 - Deficiency Rectified
Due 19 August 2024
Resolved 19 August 2024
Resolution: Crew carried out repairs. PSCO observed both doors self-close and create an effective seal.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 December 2023 Resolved
74 SOLAS (09) II-2/9.4.2.1; The fire resistance of doors shall be equivalent to that of the division in which they are fitted. Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self closing. PSCO observed 01 door from engine room to steering gear room unable to close by self.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 December 2023
Resolved 19 December 2023
Resolution: Ships personnel adjusted mechanism allowing fire door to operate as intended.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 December 2023 Resolved
74 SOLAS (20) I/11(a); The condtion of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed active leaks of hydraulic fluid in the steering gear room, as well as oily water accumulated in the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 January 2024
Resolved 21 August 2024
Resolution: Recieved Class report 073562 attesting to proper repairs of steering gear.

Ownership record