Records from 2025 to 2026. Most recent: inspection, 20 January 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 January 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the code...The engine starting systems and starting aids shall start the engine at ambient temperature of -15 degrees Celcius within two minutes of commencing starting procedure. / PSCO observed both lifeboats failing to start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2026
Resolution: Received class report attesting to rectification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2025
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF THE COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE... MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAKS ON THE MAIN ENGINE AND AUXILARY ENGINE SUPPLY FLOW METER AND FUEL DUMPERS.
74SOLAS(04) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel provided Class report attesting to deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2025
Resolved
SURFACES WITH TEMPERATURES ABOVE 220 C WHICH MAY BE IMPINGED AS A RESULT OF A FUEL SYSTEM FAILURE SHALL BE PROPERLY INSULATED. PSCO OBSERVED MULTIPLE LOCATIONS WITH FUEL SOAKED INSULATION.
74SOLAS(04) ii-2/4.2.6.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel provided Class report attesting to deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 November 2025
Resolved
"A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH THE FOLLOWING CRITERIA: THEY ARE INSULATED WITH NON COMBUSTIBLE MATERIALS. PSCO OBSERVED CONCRETE OVER STEEL A-60 BOUNDARY AND CANNOT ATTEST TO THE BOUNDARIES INTEGRITY.
74SOLAS(04) II-2/3.2.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2026
Resolution: Rcvd class report from NKK. Vsl was issued a Condition of Class due to expire 07APR2026.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2025
Resolved
STOWAGE AND CARE OF CYLINDERS. LOCKERS OR HOUSINGS MUST BE VENTED TO THE OPEN AIR NEAR THE TOP AND BOTTOM FOR POSITIVE CIRCULATION OF VAPORS. PSCO OBSERVED METAL DOOR WELDED OVER BARS SHUTTING OFF CIRCULATION TO THE STORAGE LOCKERSOF OF OXYGEN AND ACETYLENE.
46CFR147.60(B)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2026
Resolution: Rcvd Class report from NKK attesting to the proper functioning of the door.