LADY ROSEHIP

LADY ROSEHIP is a freight ship. The Coast Guard has recorded 2 inspections since 2025, most recently in January 2026, along with 5 deficiencies.

Records from 2025 to 2026. Most recent: inspection, 20 January 2026.

Built
Not recorded
Last inspected
20 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9355044
1599881
Flag
PANAMA
Maury page id
psix-1599881

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 2 calendar years (2025–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it9576 - Convention (Subpart B), Gross Ton
10630 - Dead Weight, Metric Ton
16862 - Displacement, Metric Ton
5562 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

20 January 2026 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8296868
25 November 2025 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8274036

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 January 2026 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the code...The engine starting systems and starting aids shall start the engine at ambient temperature of -15 degrees Celcius within two minutes of commencing starting procedure. / PSCO observed both lifeboats failing to start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2026
Resolution: Received class report attesting to rectification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2025 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF THE COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE... MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAKS ON THE MAIN ENGINE AND AUXILARY ENGINE SUPPLY FLOW METER AND FUEL DUMPERS. 74SOLAS(04) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel provided Class report attesting to deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2025 Resolved
SURFACES WITH TEMPERATURES ABOVE 220 C WHICH MAY BE IMPINGED AS A RESULT OF A FUEL SYSTEM FAILURE SHALL BE PROPERLY INSULATED. PSCO OBSERVED MULTIPLE LOCATIONS WITH FUEL SOAKED INSULATION. 74SOLAS(04) ii-2/4.2.6.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Vessel provided Class report attesting to deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 November 2025 Resolved
"A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH THE FOLLOWING CRITERIA: THEY ARE INSULATED WITH NON COMBUSTIBLE MATERIALS. PSCO OBSERVED CONCRETE OVER STEEL A-60 BOUNDARY AND CANNOT ATTEST TO THE BOUNDARIES INTEGRITY. 74SOLAS(04) II-2/3.2.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2026
Resolution: Rcvd class report from NKK. Vsl was issued a Condition of Class due to expire 07APR2026.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2025 Resolved
STOWAGE AND CARE OF CYLINDERS. LOCKERS OR HOUSINGS MUST BE VENTED TO THE OPEN AIR NEAR THE TOP AND BOTTOM FOR POSITIVE CIRCULATION OF VAPORS. PSCO OBSERVED METAL DOOR WELDED OVER BARS SHUTTING OFF CIRCULATION TO THE STORAGE LOCKERSOF OF OXYGEN AND ACETYLENE. 46CFR147.60(B)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2026
Resolution: Rcvd Class report from NKK attesting to the proper functioning of the door.