Records from 2019 to 2025. Most recent: inspection, 15 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)38.3 ft × 13.6 ft × 8.1 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARQUIS YACHTS LLC · PULASKI, WI, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionDiesel Electric
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
13 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
15 September 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8235120
23 December 2024
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8050461
26 September 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8010034
18 October 2023
Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7810930
11 September 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7787173
14 April 2023
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7668660
28 September 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7567539
21 April 2022
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7435427
22 October 2021
Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7341045
29 September 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7323516
27 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7209298
28 January 2020
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6897415
18 November 2019
COI Inspection · Simplified Stability Test · Initial Certification · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6858440
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines...The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Generator fuel shutoff valve located at the fuel tank connection is not fitted with a remote shutoff. Prior to using the ship's generator, install remote pull-station outside the machinery space and test in the presence of a Coast Guard Marine Inspector. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Resolved 25 September 2023
Resolution: Installed generator fuel shutoff valve outside the machinery space, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space
and engines that draw intake air from the protected space prior to release of the extinguishing agent
into the space. Powered ventilation in engine room does not shut off upon activation of fixed fire suppression system. 46CFR181.410(b)(10)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2023
Resolution: Vessel captain given training on proper switch opertation. Ventilation does correctly shutdown with fixed system, operator error resolved, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet)
in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the
ring life buoy. On-board life buoy is not at least 3 feet long and is not secured around the body of the buoy. 46CFR180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2023
Resolution: waterlight lanyard of 3 feet installed and attached around body of life buoy, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length, carrying not more than 49 passengers provided that a positive shutoff valve is installed at the hull penetration. Forward bilge pump and forward bilge pump in the engine room do not have positive shut off valves at the skin of the vessel. Install prior to next operating season.
Action required: 705 - Other - as specified
Resolved 14 April 2023
Resolution: Shut off valves were installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 September 2021
Resolved
Aspirin in first aid kit was expired. Provide new aspirin for first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 30 September 2021
Resolution: Received email from vessel operaotr with proof of aspirin purchase.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2021
Resolved
The vessel log has not been maintained for Epirb testing or life raft inspections and inconsistently for fire, abandon ship and man overboard drills. Revise log book to include all required lifesaving maintenance and drill entries. Deficiency to be cleared prior operating in the spring 2022.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 21 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2021
Resolved
Vessel is on a LBS route and is required to carry x3 hand held red flares iaw 160.021. And x3 orange smoke distress signals iaw 160.037. Vessels orange smoke flares had expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 28 May 2021
Resolution: Owner purchased new unexpired orange smoke flares iaw 160.037 and placed them onboard the vessel in the distress signal container.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
Adjust pull angle on Emergency fuel shutoff cable to valve to prevent binding.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 14 July 2020
Resolution: RCVD video of corrected fuel pull, all sat