Records from 2019 to 2026. Most recent: inspection, 19 April 2026.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 April 2025
Resolved
A hatch exposed to the weather must be watertight. MI found 4+ft of water in both stbd and port fwd void spaces. Remove water and replace gaskets to satisfaction of USCG marine inspector.
46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emrgency. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] to outboards must be approved by the OCMI.
46 CFR 182.200
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2025
Resolution: MSC Approved changes
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three, 2.5 gal buckets with an attached lanyard...One fire bucket was broken. Replace fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: New fire bucket provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024
Resolved
A visual indicator must be provided at the op station to indicate when any automatic bilge pump is operating. Port, forward bilge pump indicator light did not illumincate upon testing. Repair and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Proof of functioning bilge pump indicator light provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 April 2024
Resolved
The person in command of a documented vessel must have on board the original COD...Copy of COD currently in effect provided onboard. Locate original COD and place on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 9 May 2024
Resolution: Certified copy provided.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 April 2024
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Float free hydrostatic release unit secured with zip ties to vessel.
Action required: 10 - Deficiency Rectified
Resolved 25 April 2024
Resolution: Shackle installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 April 2024
Resolved
...Drills and training shall be logged...the drill entry shall include a general description of the drill scenario and training topics. Drill log lacked a description of the drill scenario/training topics.
Action required: 10 - Deficiency Rectified
Resolved 25 April 2024
Resolution: Educated captain on logging requirements.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 19 April 2023
Resolved
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least 205 millimeters (8 inches) in length and 25 millimeters (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint. Proplerly place loading marks onto vessels hull at the next dry dock. NLT 31 MAR 2024 / 46 CFR 185.602
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2024
Resolution: Loading marks installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 April 2023
Resolved
Mandatory chemical testing following serious marine incidents. A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Replace expired ALCO test strips. 46 CFR 185.212
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2023
Resolution: Owner purchased new un expired ALCO test strips - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Vessels life ring buoy floating light does not have batteries installed. Install proper batteries and test float light. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2023
Resolution: Operator installed batteries and tested float light - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The marking is not required on a life jacket carried to meet a temporary need for additional life jackets, if the life jacket has the name of another vessel or company marked on it. For an immersion suit, the name of the person to whom the immersion suit is assigned is an acceptable alternative to the name of the vessel. One child life jacket missing vessels name, stencil vessels name onto the same. 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 May 2023
Resolution: Operator stenciled vessels name onto the lifejacket - all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 April 2023
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate:
(1) Two years for individuals serving on vessels to which STCW applies unless the mariner is under the age of 18, in which case the maximum period of validity will be 1 year.
(2) Five years for all other mariners. Master did not have his medical certificate onboard at time of the inspection. Provide MC at all time while operating under the capciity of master MMC. 46 CFR 15.401
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2023
Resolution: Master located his medical certificate which was valid and placed onboard with his MMC - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 April 2022
Resolved
Vessel is required to carry survival craft IAW its COI. Vessel does not currently have IBAs onboard due to servicing. 46 CFR 180.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2022
Resolution: Received photos of installed IBAs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 April 2022
Resolved
Hydrostatic release unit is required to be replaced every 2 years. Hydrostatic release unit for the EPIRB expired 7/21. 46 CFR 185.740(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2022
Resolution: Received photo of newly installed hydrostatic release unit.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 14 April 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 21 April 2022
Resolved 22 April 2022
Resolution: Received photo of marine radio operator permit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2022
Resolved
First aid kit needs to be approved IAW 46 CFR 160.041. Ammonia inhalants expired. Missing aspirin. Provide new items within 7 days. 46 CFR 184.710 & 46 CFR 160.041-4
Action required: 705 - Other - as specified
Due 30 May 2022
Resolved 17 June 2022
Resolution: New first aid kit items provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 14 April 2022
Resolved
Pre-employment drug testing results could not be provided. Enroll in testing program. 46 CFR 16.210 & 230
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: Received consortium certificate and list of employees.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 14 April 2022
Resolved
Stability letter to be posted at the operating station. Stability letter not posted on the bridge. 46 CFR 176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 22 April 2022
Resolution: Stability letter posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 14 April 2022
Resolved
Each vessel must be marked with permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the max allowable trim and amidships to indicate the max allowable draft. No hull markings present. Permanently mark vessel during next drydock.
Action required: 705 - Other - as specified
Resolved 15 May 2023
Resolution: Added new CG835 to the 2023 annual inspection activity and reissued to the owner since they lost the original CG835.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 July 2021
Resolved
Fuel shut off valves shall be labeled. Properly label diesel heater fuel tank shut off valves. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 27 July 2021
Resolution: Vessel rep Colleen sent photos of labeled diesel fuel heater shut off valves.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 July 2021
Resolved
Vessel required to carry current year navigation publications & manuals. Vessel tide and current tables are not up-to-date. 46 CFR 184.420(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 27 July 2021
Resolution: Vessel rep Colleen sent photos of 2021 tide and current tables.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2021
Resolved
Vessel is required to have a first aid kit. First aid items are expired (aspirin). 46 CFR 160.041-4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 2 August 2021
Resolution: Vessel rep colleen sent photo of new aspirin placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2020
Resolved
Remove all combustible trash can and replace with non-combustible ones.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 11 March 2021
Resolution: vessel has repalced all trash cans
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 October 2020
Resolved
Post all required paperwork onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2020
Resolved 11 March 2021
Resolution: vessel has posted all paperwork.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 October 2020
Resolved
Correctly label new flare storage location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 11 March 2021
Resolution: Flares have been returned to orginal local
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 October 2020
Resolved
Provide As appropriate for the intended voyage, up-to-
date:Charts of large enough scale to make safe
navigation possible,and Tide tables
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2020
Resolved 11 March 2021
Resolution: vessel has provide new charts and tide tables