Records from 2019 to 2026. Most recent: inspection, 7 August 2026.
Inspection history · 22
7 August 2026
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8457760
15 June 2026
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8405656
22 April 2026
Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8354368
8 April 2026
Deficiency Check · Drydock Exam · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8345066
18 September 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8241568
21 May 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8141692
30 April 2025
COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050436
1 August 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7971937
22 May 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855583
27 March 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855580
29 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640393
13 May 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7460687
3 May 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7443161
13 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7429993
3 December 2021
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 7362657
9 August 2021
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7281818
9 August 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7281941
7 July 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7250885
21 April 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7180280
7 July 2020
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6999729
6 April 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6943016
1 December 2019
Construction Oversight · Deadweight Survey · Initial Certification · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6903532
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2026
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. The simplex hull strainer, located in the port side engine compartment, is not in suitable condition. Hull strainer is leaking sea water into engine compartment. Repair or replace hull strainer to the satisfaction of the attending marine inspector. 46 CFR 182.420(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2026
Resolution: Simplex strainer was suitably repaired and is no longer leaking water.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 22 April 2026
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include—(1) Closing the sea cock and removing the handle;(2) Padlocking the sea cock in the closed position;(3) Using a non-releasable wire-tie to hold the sea cock in the closed position; or(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock. The overboard discharge valve on the marine sanitation device on board is not secured by any means listed above. Secure the overboard discharge valve to the satisfaction of the attending marine inspector. 46 CFR 184.704 33 CFR 159.7 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: Crew secured valve handle with zip ties.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2026
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Engine start battery for port engine has wing nuts. Replace wing nuts to permanent type connectors to the satisfaction of the attending marine inspector. 46 CFR 183.350 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: All wing nuts were removed and replaced with permanent type connectors.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 April 2026
Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. Steering gear in starboard compartment does not have a rudder stop on the outboard side. Provide suitable rudder stop on the outboard side of the starboard steering gear to the satisfaction of the attending marine inspector. 46 CFR 182.610(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: Rudder stop was suitably installed on outboard port side steering gear.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel has expired aspirin. Replace with required 48 doses to the satisfaction of the attending marine inspector. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 6 May 2026
Resolution: Vessel obtained 48 doses of asprin. Photo uploaded under "documents" of this section.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 April 2026
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. No evidence provided of supervisor and crew drug awareness training. Provide documentation of the training described above to the satisfaction of the attending marine inspector. 46 CFR 16.113(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 1 June 2026
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2026
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No evidence of drill log book on board. Create log book and provide documentation to the satisfaction of the attending marine inspector. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 6 May 2026
Resolution: Drill log book created in electronic format with description of drills, duties for each crew member, and required training intervals for each employed member. Photos have been uploaded under "documents" of this section.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2026
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. The fuel vent on the starboard side of the vessel is corroded. Repair or replace vent to the satisfaction of the attending marine inspector. 46 CFR 182.450(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: Fuel tank vent was repaired and no corrosion is present.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2026
Resolved
Except as noted in § 176.114 of this part, each vessel inspected and certificated under the provisions of this sub chapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel Certificate of
Inspection (COI) has Sector Honolulu's Work Instruction 31 (WI-31) in the COI's Route Permitted and Conditions of Operation. The required WI-31 medical oxygen cylinder
is overdue for its five-year hydrostatic test by one
year and two months in accordance with 49 CFR 180.209
Table 1. Conduct the required hydrostatic test on oxygen
cylinder or replace with a compliant oxygen cylinder
to the satisfaction of the attending marine inspector. 46 CFR 176.100(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 13 May 2026
Resolution: Bottle recieved hydrostatic testing. Photo of bottle and documentation uploaded under "documents" of this tab.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2026
Resolved
Each survival craft, rescue boat, and launching appliance on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. One life float on board the vessel vinyl covering is excessively cracked exposing the polystyrene core. Repair with an approved vinyl repair kit or replace life float to the satisfaction of the attending marine inspector. 46 CFR 185.722
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 6 May 2026
Resolution: Life float has been repaired. Photo has been uploaded under "documents" of this section.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 April 2026
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Deck rails must include a top rail with the minimum height required, and lower courses or equivalent protection as required. The vessel's forward bow from port to starboard does not have deck rails or approved equivalent protection. Submit a written policy addressing how the vessel will implement physical or operational measures to a level that is considered an equivalent protection to railings to be approved by the OCMI. 46 CFR 177.900(a), (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 24 April 2026
Resolution: Vessel submitted poicy that is IAW WI-22. Uploaded under documents on the vessel's profile.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2026
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Vessel has not completed sea trials under sail following 6yr mast inspection. Vessel is restricted from operating under sail until sea trials are completed under sail.
Action required: 705 - Other - as specified
Resolved 13 April 2026
Resolution: MI witnessed sea trials while under sail; all sat.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 30 April 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The sail equipment preventive maintenance plan (PMP) was not carried out by the crew. Provide a third party sail rigging survey report and record PMP carried out by the owner or operators to the satisfaction of the attending Marine Inspector.
46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 14 May 2025
Resolution: Received third party sail rigging report. No significant safety concern identified by surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 10 child sized life jackets were missing the functional retroreflective material. Repair the life jackets to satisfaction of the attending Maine Inspector. Limit the passengers allowable onboard to adults only until the life jackets are repaired or replaced.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
Resolution: Corrected, received photograph proof.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 April 2025
Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The lifefloat was missing the functional retroreflective material. Repair the lifefloat to satisfaction of the attending Maine Inspector.
46 CFR 180.200(2)
46 CFR 160.010-4(p)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
Resolution: Corrected, received photograph proof.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The storage spaces for both adult and child size life jackets are not properly marked. Mark the life jacket storage spaces to the satisfaction of the attending Marine Inspector.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 15 May 2025
Resolution: Corrected, received photograph proof.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 April 2025
Resolved
Man overboard and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drill entries were missing on the log. Crew conducted drills and made entries during the inspection.
46 CFR 185.520(f)
46 CFR 185.524(d)
Action required: 10 - Deficiency Rectified
Resolved 30 April 2025
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 30 April 2025
Resolved
The master shall ensure that the pollution prevention placards are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. The garbage pollution prevention placard was not displayed at location readily accessible to the passengers. Placard displayed on the passenger space.
46 CFR 184.702
33 CFR 151.59(a)
Action required: 10 - Deficiency Rectified
Resolved 30 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 March 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh.
Vessel has no installed flame screens on fuel vents.
46 CFR 182.450(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 24 April 2023
Resolution: Received photograph from vessel rep of flame arrestor screen and vent housing mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 March 2023
Resolved
Where a flexible vent pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration. Fuel tank vent hoses in both port and starboard engine compartments, have Type B2 rated hose. Replace tank vent hoses with Type A1 or A2 hose.
46CFR182.450(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 20 April 2023
Resolution: Received photograph of tank vent hose replaced with A2 fuel hose.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 March 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Cracks found in top of life float. Repair cracks found in life float.
46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 20 April 2023
Resolution: Received photograph of lifefloat cracks repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Fractured welds on deck effecting strength of railings. Repair all fractured welds found.
46 CFR 177.900 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2023
Resolved 20 April 2023
Resolution: Received photgraphs from vessel rep. of the fractured weld repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2022
Resolved
Pipes used for wet exhaust lines must be schedule 80 or corrosion-resistant material. STBD engine exhaust piping require replacement due to running rust and excessive corrosion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 28 April 2022
Resolution: Vessel emailed video of new piping installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 April 2022
Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. Life float requires retro tape replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 4 May 2022
Resolution: Resolved deficiency by attaching new retro tape.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 April 2022
Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Master's radio operator permit not onboard.
47 CFR 80.158 (e)
Action required: 10 - Deficiency Rectified
Due 13 April 2022
Resolved 13 April 2022
Resolution: Master provided proof of valid Marine radio operator permit via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 August 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel's electronic throttle control system failed, resulting in a loss of propulsion. The electronic throttle control shall be repaired or replaced to the satisfaction of the attending USCG Marine Inspector and the proper operation of the vessel's propulsion system shall be demonstrated to the attending USCG Marine Inspector.
46 CFR 182.100
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2021
Resolution: Attended vessel and verified proper function of propulsion system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2021
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel spars, standing rigging, running rigging,blocks, fittings, and sails. The vessel did not have onboard the preventative maintenance plan available for review. Provide a copy of the vessel's current PMP for review IAW NVIC 02-16.
46CFR176.802(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2021
Resolution: Reviewed vessel's PMP and all found satisfactory IAW NVIC 02-16.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2021
Resolved
The owner shall be prepared to conduct tests of the following: Operational test of the means provided for pumping the bilges. The crew onboard was unfamiliar with operation of the fixed bilge system. Emergency procedures were updated and crew demonstrated operation to the satisfaction of the attending Marine Inspector.
46CFR176.804(h)
Action required: 10 - Deficiency Rectified
Resolved 21 April 2021
Resolution: Emergency operating procedures updated and training conducted in the presence of the Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 July 2020
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. During operational test of fire pump, pressure gauge at outlet was inoperative.
46 CFR 181.300(b)
Action required: 10 - Deficiency Rectified
Resolved 7 July 2020
Resolution: Vessel procured new pressure gauge and tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2020
Resolved
Upon arrival to operating [name withheld], vessel must have new to zone conducted.
46 CFR 176.404
Action required: 705 - Other - as specified
Resolved 7 July 2020
Resolution: Completed satisfactory new to zone inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 May 2020
Resolved
Vessel crew not in St. Croix, unable to conduct drills. Drills to be conducted to the satisfaction of local marine inspector.
46 CFR 185.520
46 CFR 185.524
Action required: 705 - Other - as specified
Resolved 7 July 2020
Resolution: Completed satisfactory drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2020
Resolved
Life jackets are not currently stowed in final location, that is practicable and readily available. Life jackets to be stowed to satisfaction of Local Marine Inspector.
46 CFR 185.602(c)
Action required: 705 - Other - as specified
Resolved 7 July 2020
Resolution: Lifejackets stowed in adequate location.