ADVANTAGE VIRTUE is a 2009 tank ship. The Coast Guard has recorded 3 inspections since 2020, most recently in December 2023, along with 3 deficiencies.
Records from 2020 to 2023. Most recent: inspection, 27 December 2023.
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ADVANTAGE VIRTUE, retrieved 18 September 2026. mauryrecords.com/v/psix-1602385.html
Documentation record
Tonnage as PSIX records it296481 - Dead Weight, Ton 339111 - Displacement, Ton 98937 - Convention (Subpart B), Net Ton 156726 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
27 December 2023PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7839169
30 May 2022PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7463222
27 May 2020COC-TVE Renew · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6954175
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 December 2023Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHWERE FLAMMABLE MIXTURES ARE ABLE TO COLLECT. PSCO OBSERVED 02 NON EXPLOSION PROFF LIGHTS IN STBD DECK LOCKER, 01 NON EXPLOSION LIGHT IN PORT DECK LOCKER, AND ELECTRICAL BOX FLANGE ON DECK WAS MISSING BLANK FLANGE. BLANK FLANGE WAS RECTIFIED.
74SOLAS(09)II-1/45.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2024
Resolved 30 December 2023
Resolution: Received tech report from ABS attesting that the two non-Ex rated lighting fixtures inside of the STBD deck locker were removed, and the one non-Ex rated lighting fixture inside of the port deck locker was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 December 2023Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THESE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 02 NON EX LIGHTS IN THE PUMP ROOM. LIGHTS NEED TO BE REPLACED WITH PROPER EX RATED LIGHTS PRIOR TO DISCHARGE OF CARGO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2024
Resolved 30 December 2023
Resolution: Received tech report from ABS indicating the two non-Ex rated lights in the cargo pump room were removed and replaced with onboard spare ex lights.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 December 2023Resolved
TANK OVERFILL ALARM SHALL BE IDENTIFIED WITH A LEGEND "TANK OVERFILL ALARM" IN BLACK LETTERS 2 INCHES HIGH ON WHITE BACKGROUND. PSCO OBSERVED SIGNAGE FOR TANK OVERFILL ALARD NOT PAINTED.
46CFR39.2007(d)(2)
Action required: 10 - Deficiency Rectified
Resolved 27 December 2023
Resolution: CREW PAINTED THE TANK OVERFILL ALARM SIGNAGE PRIOR TO PSC TEAM'S DEPARTURE OF VESSEL.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.